Literature DB >> 14734979

An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients: preliminary experiences in 10 consecutive cases.

Jangbo Lee1, Kazutoshi Hida, Toshitaka Seki, Yoshinobu Iwasaki, Akino Minoru.   

Abstract

BACKGROUND: Lumbar spinal stenosis (LSS) is often a position-dependent condition that is aggravated in extension and relieved in flexion.
METHODS: Ten consecutive elderly patients with LSS were assessed postoperatively by magnetic resonance imaging and the Swiss Spinal Stenosis Questionnaire. Cross-sectional areas of the dural sac and intervertebral foramina at the stenotic level were measured postoperatively and compared with the preoperative values.
RESULTS: Postoperatively the cross-sectional area of the dural sac increased 16.6 mm2 or 22.3% and intervertebral foramina increased 22 mm2 or 36.5%. The intervertebral angle and the posterior disc height changed significantly. Seventy percent of the patients were satisfied with the surgical outcome.
CONCLUSION: This new surgical method is effective in elderly LSS patients.

Entities:  

Mesh:

Year:  2004        PMID: 14734979     DOI: 10.1097/00024720-200402000-00013

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  28 in total

1.  The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis.

Authors:  Zongmiao Wan; Shaobai Wang; Michal Kozanek; Qun Xia; Frederick L Mansfield; Guohua Lü; Kirkham B Wood; Guoan Li
Journal:  Eur Spine J       Date:  2011-09-21       Impact factor: 3.134

2.  Long-term reduction in pain and disability after surgery with the interspinous device for intervertebral assisted motion (DIAM) spinal stabilization system in patients with low back pain: 4-year follow-up from a longitudinal prospective case series.

Authors:  Josip Buric; Massimiliano Pulidori
Journal:  Eur Spine J       Date:  2011-01-29       Impact factor: 3.134

Review 3.  Role of lumbar interspinous distraction on the neural elements.

Authors:  Alex Alfieri; Roberto Gazzeri; Julian Prell; Christian Scheller; Jens Rachinger; Christian Strauss; Andreas Schwarz
Journal:  Neurosurg Rev       Date:  2012-05-02       Impact factor: 3.042

4.  [Longterm results of the interspinous spacer X-STOP].

Authors:  A Reinhardt; S Hufnagel
Journal:  Orthopade       Date:  2010-06       Impact factor: 1.087

5.  Biomechanical evaluation of the X-Stop device for surgical treatment of lumbar spinal stenosis.

Authors:  Zongmiao Wan; Shaobai Wang; Michal Kozánek; Peter G Passias; Frederick L Mansfield; Kirkham B Wood; Guoan Li
Journal:  J Spinal Disord Tech       Date:  2012-10

6.  IPD without bony decompression versus conventional surgical decompression for lumbar spinal stenosis: 2-year results of a double-blind randomized controlled trial.

Authors:  Wouter A Moojen; Mark P Arts; Wilco C H Jacobs; Erik W van Zwet; M Elske van den Akker-van Marle; Bart W Koes; Carmen Lam Vleggeert-Lankamp; Wilco C Peul
Journal:  Eur Spine J       Date:  2015-01-14       Impact factor: 3.134

7.  Market approval processes for new types of spinal devices: challenges and recommendations for improvement.

Authors:  Arno Bisschop; Maurits W van Tulder
Journal:  Eur Spine J       Date:  2016-05-27       Impact factor: 3.134

8.  Biomechanical analysis of a new lumbar interspinous device with optimized topology.

Authors:  Chen-Sheng Chen; Shih-Liang Shih
Journal:  Med Biol Eng Comput       Date:  2018-01-06       Impact factor: 2.602

9.  Does an interspinous device (Coflex) improve the outcome of decompressive surgery in lumbar spinal stenosis? One-year follow up of a prospective case control study of 60 patients.

Authors:  Alexander Richter; Christian Schütz; Michael Hauck; Henry Halm
Journal:  Eur Spine J       Date:  2009-12-05       Impact factor: 3.134

10.  The Felix-trial. Double-blind randomization of interspinous implant or bony decompression for treatment of spinal stenosis related intermittent neurogenic claudication.

Authors:  Wouter A Moojen; Mark P Arts; Ronald Brand; Bart W Koes; Wilco C Peul
Journal:  BMC Musculoskelet Disord       Date:  2010-05-27       Impact factor: 2.362