Literature DB >> 14723507

Accuracy limitations of chronaxie values.

Leslie A Geddes1.   

Abstract

The strength-duration curve is a plot of the threshold current (I) versus pulse duration (d) required to stimulate excitable tissue. On this curve are two points: 1) rheobase (b) and 2) chronaxie (c). Rheobase is the threshold current for an infinitely long-duration stimulus. Chronaxie, the excitability constant, is the duration of a pulse of current of twice rheobasic strength. The mathematical expression for the strength-duration curve is I = b(1 + c/d). Although there are many published values for chronaxie for various excitable tissues, the range of variability for a given tissue type is quite large. This paper identifies five factors that can affect the accuracy of chronaxie measurement and shows that the most reliable values can be obtained with a rectangular pulse delivered from a constant-current source.

Mesh:

Year:  2004        PMID: 14723507     DOI: 10.1109/TBME.2003.820340

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  23 in total

1.  Pulsed laser versus electrical energy for peripheral nerve stimulation.

Authors:  Jonathon Wells; Peter Konrad; Chris Kao; E Duco Jansen; Anita Mahadevan-Jansen
Journal:  J Neurosci Methods       Date:  2007-03-31       Impact factor: 2.390

2.  Chronic intravitreous infusion of ciliary neurotrophic factor modulates electrical retinal stimulation thresholds in the RCS rat.

Authors:  Tiffany L Kent; Inna V Glybina; Gary W Abrams; Raymond Iezzi
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-01       Impact factor: 4.799

3.  Pulse width dependence of motor threshold and input-output curve characterized with controllable pulse parameter transcranial magnetic stimulation.

Authors:  Angel V Peterchev; Stefan M Goetz; Gregory G Westin; Bruce Luber; Sarah H Lisanby
Journal:  Clin Neurophysiol       Date:  2013-02-20       Impact factor: 3.708

4.  Effects of pulse duration on magnetostimulation thresholds.

Authors:  Emine U Saritas; Patrick W Goodwill; Steven M Conolly
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

5.  Effect of coil orientation on motor-evoked potentials in humans with tetraplegia.

Authors:  Hang Jin Jo; Vincenzo Di Lazzaro; Monica A Perez
Journal:  J Physiol       Date:  2018-09-13       Impact factor: 5.182

6.  Photoelectric artefact from optogenetics and imaging on microelectrodes and bioelectronics: New Challenges and Opportunities.

Authors:  Takashi D Y Kozai; Alberto L Vazquez
Journal:  J Mater Chem B       Date:  2015-07-07       Impact factor: 6.331

Review 7.  Electroconvulsive therapy stimulus parameters: rethinking dosage.

Authors:  Angel V Peterchev; Moacyr A Rosa; Zhi-De Deng; Joan Prudic; Sarah H Lisanby
Journal:  J ECT       Date:  2010-09       Impact factor: 3.635

8.  Easy method to examine single nerve fiber excitability and conduction parameters using intact nonanesthetized earthworms.

Authors:  Robert Bähring; Christiane K Bauer
Journal:  Adv Physiol Educ       Date:  2014-09       Impact factor: 2.288

9.  A model for transcutaneous current stimulation: simulations and experiments.

Authors:  Andreas Kuhn; Thierry Keller; Marc Lawrence; Manfred Morari
Journal:  Med Biol Eng Comput       Date:  2008-11-13       Impact factor: 2.602

10.  Strength-duration relationship for intra- versus extracellular stimulation with microelectrodes.

Authors:  F Rattay; L P Paredes; R N Leao
Journal:  Neuroscience       Date:  2012-04-16       Impact factor: 3.590

View more