Literature DB >> 14700290

Comparison of wound-healing characteristics with feedback circuit electrosurgical generators in a porcine model.

Harrison S Pollinger1, Gamal Mostafa, Kristi L Harold, Catherine E Austin, Kent W Kercher, Brent D Matthews.   

Abstract

The type of incisional instrument used to create a surgical wound can influence the rate of wound healing and overall wound strength. The purpose of this study was to evaluate several facets of wound healing within incisions created in the small intestine, uterus, and skin in a porcine model by using feedback circuit electrosurgical generators and a standard steel scalpel blade in a porcine model. Eighteen pigs were evaluated by creating surgical incisions in the skin, uterus, and small intestine utilizing 2 computerized electrosurgical generators (FX, ValleyLab, Boulder, CO, and PEGASYS, Ethicon Endo-Surgery, Inc., Cincinnati, OH) and a scalpel blade. All incisions were reapproximated with absorbable suture. Incision sites were evaluated histologically at 3, 7, or 14 days postincision according to randomization. The skin and small intestine samples were tested for wound tensile strength at 7 and 14 days. There were no statistically significant differences demonstrated with tensile strength testing comparing the electrosurgical devices to the scalpel-blade incisions for skin or small intestine at all time points. The only significant difference detected with respect to wound tensile strength was when different organ types were compared, regardless of device used (i.e., skin, 19.5 N/cm2 vs. small intestine, 5.78 N/cm2). Histologic evaluation demonstrated that the wounds created by the electrosurgical generators displayed decreased overall wound healing at 3, 7, and 14 days compared to the scalpel group. These findings indicate that the electrosurgical devices tested delay wound healing at the surgical site, but fail to demonstrate any significant difference in overall wound tensile strength. Wound healing may occur at a more rapid rate when a traditional scalpel blade is used to create the surgical incision, but no difference in global wound dynamics could be detected.

Entities:  

Mesh:

Year:  2003        PMID: 14700290

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  10 in total

1.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) versus conventional electro surgery in post-bariatric body-contouring procedures: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Pablo Ramirez; Marc-Oliver Riener; Gabriel Djedovic; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-04-01       Impact factor: 3.315

2.  Effect of low-thermal dissection device versus conventional electrocautery in mastectomy for female-to-male transgender patients.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Jens Rothenberger; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2020-05-05       Impact factor: 3.315

3.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) vs conventional electrosurgery in post-bariatric abdominoplasty: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Marc-Oliver Riener; Robert Sader; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-09-17       Impact factor: 3.315

4.  Incidence and characteristics of vaginal cuff dehiscence in robotic-assisted and traditional total laparoscopic hysterectomy.

Authors:  Erin Dauterive; George Morris
Journal:  J Robot Surg       Date:  2011-09-13

5.  Ultrasonic thermal damage during robotic hysterectomy.

Authors:  Jason Massengill; Eric Lombardini; Jonathan Oliva; Jerome Buller; Daniel Gruber
Journal:  J Robot Surg       Date:  2014-04-27

6.  Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector.

Authors:  Albert Y Wu; Thomas J Baldwin; Bhupendra C Patel; Jeffrey W Clymer; Ryan D Lewis
Journal:  Med Res Innov       Date:  2017-10-27

7.  Traditional electrosurgery and a low thermal injury dissection device yield different outcomes following bilateral skin-sparing mastectomy: a case report.

Authors:  Richard E Fine; Joshua G Vose
Journal:  J Med Case Rep       Date:  2011-05-28

8.  Electrocautery Devices With Feedback Mode and Teflon-Coated Blades Create Less Surgical Smoke for a Quality Improvement in the Operating Theater.

Authors:  Tobias Kisch; Eirini Liodaki; Robert Kraemer; Peter Mailaender; Matthias Brandenburger; Veronika Hellwig; Felix H Stang
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.817

9.  Comparative study of wound healing in rat skin following incision with a novel picosecond infrared laser (PIRL) and different surgical modalities.

Authors:  Hannes Petersen; Fatemeh Tavakoli; Sebastian Kruber; Adrian Münscher; Alexandra Gliese; Nils-Owe Hansen; Stephanie Uschold; Dennis Eggert; Wesley D Robertson; Tobias Gosau; Susanne Sehner; Marcel Kwiatkowski; Hartmut Schlüter; Udo Schumacher; Rainald Knecht; R J Dwayne Miller
Journal:  Lasers Surg Med       Date:  2016-03-04       Impact factor: 4.025

10.  Enhanced electroscalpel incisional wound healing potential of honey in wistar rats.

Authors:  David O Eyarefe; David I Kuforiji; Theophilus A Jarikre; Benjamin O Emikpe
Journal:  Int J Vet Sci Med       Date:  2017-11-13
  10 in total