Literature DB >> 14690184

Variability of quantitative coronary angiography: an evaluation of on-site versus core laboratory analysis.

Rasmus Moer1, Anton W M van Weert, Yngvar Myreng, Per Mølstad.   

Abstract

To assess the validity of locally performed off-line quantitative coronary angiography (QCA) measurement in clinical trials, we carried out a comparative study between on-site QCA analysis and analysis performed at an independent external core laboratory. One local operator analyzed the pre, post and follow-up angiograms of 116 patients participating in the Stenting in Small Coronary Arteries Study (SISCA) prior to final QCA analysis in the core laboratory. The mean values of the reference diameter (RD), minimal lumen diameter (MLD) and diameter stenosis (DS) showed acceptable agreement between study site and core laboratory. However, on the level of individuals the interobserver differences were large, affecting the outcome of restenosis rate significantly, and in a such way that the conclusions in the SISCA trial might have come out differently if a core laboratory had not been used. This emphasizes the importance of using independent core laboratories in coronary interventional trials.

Entities:  

Mesh:

Year:  2003        PMID: 14690184     DOI: 10.1023/b:caim.0000004327.52633.d2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  8 in total

1.  Stenting in small coronary arteries (SISCA) trial. A randomized comparison between balloon angioplasty and the heparin-coated beStent.

Authors:  R Moer; Y Myreng; P Mølstad; P Albertsson; P Gunnes; B Lindvall; R Wiseth; K Ytre-Arne; J Kjekshus; S Golf
Journal:  J Am Coll Cardiol       Date:  2001-11-15       Impact factor: 24.094

2.  ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions.

Authors:  P J Scanlon; D P Faxon; A M Audet; B Carabello; G J Dehmer; K A Eagle; R D Legako; D F Leon; J A Murray; S E Nissen; C J Pepine; R M Watson; J L Ritchie; R J Gibbons; M D Cheitlin; T J Gardner; A Garson; R O Russell; T J Ryan; S C Smith
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

3.  One core laboratory at two international sites, is that feasible? An inter-core laboratory and intra-observer variability study.

Authors:  Joan C Tuinenburg; Gerhard Koning; Ellen Hekking; Colette Desjardins; François Harel; Luc Bilodeau; Anton W M van Weert; Jacques Lespérance; Johan H C Reiber
Journal:  Catheter Cardiovasc Interv       Date:  2002-07       Impact factor: 2.692

4.  Comparison of different quantitative coronary analysis systems: ARTREK, CAAS, and CMS.

Authors:  J Hausleiter; C W Nolte; S Jost; B Wiese; M Sturm; P R Lichtlen
Journal:  Cathet Cardiovasc Diagn       Date:  1996-01

5.  Reproducibility of quantitative coronary analysis, Assessment of variability due to frame selection, different observers, and different cinefilmless laboratories.

Authors:  P A Sirnes; Y Myreng; P Mølstad; S Golf
Journal:  Int J Card Imaging       Date:  1996-09

6.  New approach to quantitative angiographic assessment after stent implantation.

Authors:  B Reimers; C Di Mario; L Di Francesco; I Moussa; S Blengino; G Martini; J H Reiber; A Colombo
Journal:  Cathet Cardiovasc Diagn       Date:  1997-04

7.  Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.

Authors:  J H Reiber; P W Serruys; C J Kooijman; W Wijns; C J Slager; J J Gerbrands; J C Schuurbiers; A den Boer; P G Hugenholtz
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

  8 in total
  1 in total

1.  Angiographic core laboratory reproducibility analyses: implications for planning clinical trials using coronary angiography and left ventriculography end-points.

Authors:  Terje K Steigen; Cheryl Claudio; David Abbott; Michael Schulzer; Jeff Burton; Wayne Tymchak; Christopher E Buller; G B John Mancini
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-12       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.