Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.

J H Reiber, P W Serruys, C J Kooijman, W Wijns, C J Slager, J J Gerbrands, J C Schuurbiers, A den Boer, P G Hugenholtz.   

Abstract

A computer-assisted technique has been developed to assess absolute coronary arterial dimensions from 35 mm cineangiograms. The boundaries of optically magnified and video-digitized coronary segments and the intracardiac catheter are defined by automated edge-detection techniques. Contour positions are corrected for pincushion distortion. The accuracy and precision of the edge detection procedure as assessed from cinefilms of contrast-filled acrylate (Perspex) models were -30 and 90 micrometers, respectively. The variability of the analysis procedure itself in terms of absolute arterial dimensions was less than 0.12 mm, and in terms of percentage arterial narrowing for coronary obstructions less than 2.74%. Short-, medium-, and long-term variability measurements were assessed from repeated coronary angiographic examinations performed 5 min, 1 hr, and 90 days apart, respectively. For all studies the mean differences in absolute diameters were less than 0.13 mm. The variability in obstruction diameter ranged from 0.22 mm for the best-controlled study (medium-term) to 0.36 mm for the least-controlled study (long-term); variability in reference diameter ranged from 0.15 to 0.66 mm, respectively. It is concluded that the biological variations are a source of major concern and that further attempts toward standardization of the angiographic procedure are seriously needed.

Entities:  

Mesh:

Year:  1985        PMID: 3965172     DOI: 10.1161/01.cir.71.2.280

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  97 in total

1.  Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries.

Authors:  D M Whelan; W J van der Giessen; S C Krabbendam; E A van Vliet; P D Verdouw; P W Serruys; H M van Beusekom
Journal:  Heart       Date:  2000-03       Impact factor: 5.994

Review 2.  The effect of DICOM on QCA and clinical trials.

Authors:  J H Reiber; G Koning; B Goedhart
Journal:  Int J Card Imaging       Date:  1998

Review 3.  Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler.

Authors:  David E Newby; Keith A A Fox
Journal:  Br J Clin Pharmacol       Date:  2002-06       Impact factor: 4.335

4.  Comparison of digital and cine coronary arteriography.

Authors:  J C Gurley; S E Nissen
Journal:  Int J Card Imaging       Date:  1990

5.  Restenosis following coronary angioplasty.

Authors:  K J Beatt; P W Serruys
Journal:  Int J Card Imaging       Date:  1990

6.  Variability of quantitative coronary angiography: an evaluation of on-site versus core laboratory analysis.

Authors:  Rasmus Moer; Anton W M van Weert; Yngvar Myreng; Per Mølstad
Journal:  Int J Cardiovasc Imaging       Date:  2003-12       Impact factor: 2.357

7.  A novel approach for the detection of pathlines in X-ray angiograms: the wavefront propagation algorithm.

Authors:  Johannes P Janssen; Gerhard Koning; Patrick J H de Koning; Joan C Tuinenburg; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2002-10       Impact factor: 2.357

8.  Restenosis after coronary angioplasty: a proposal of new comparative approaches based on quantitative angiography.

Authors:  P W Serruys; D P Foley; P J de Feyter
Journal:  Br Heart J       Date:  1992-10

9.  Clinical and angiographic variables affecting the progression of coronary artery disease as determined by quantitative angiography.

Authors:  A Joseph; J D Talley; A Shih; T Crum; R Vogel; J Kupersmith
Journal:  Int J Card Imaging       Date:  1994-09

10.  Correlation between clinical course and quantitative analysis of the ischemia related artery in patients with unstable angina pectoris, refractory to medical treatment. Results of two randomized trials. The European Cooperative Study Group.

Authors:  M J van den Brand; A van Miltenburg; M J de Boer; L R van der Wieken; P J de Feyter; M L Simoons
Journal:  Int J Card Imaging       Date:  1994-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.