New approach to quantitative angiographic assessment after stent implantation.

B Reimers1, C Di Mario, L Di Francesco, I Moussa, S Blengino, G Martini, J H Reiber, A Colombo.   

Abstract

The new generation quantitative angiographic systems apply the interpolated technique to calculate the reference diameter at the site of the stenosis by integrating measurements of the segments proximal and distal to the stenosis. After stent implantation these measurements can be misleading as the treated segment, which is frequently larger than the adjacent not stented segments, is included in the measurements. The consequence is an overestimation of the reference diameter and the residual diameter stenosis. The present study was performed to compare this conventional technique of measurement with a new method which excludes the stented segment for the calculation of the reference diameter. Fifty-two lesions treated with poorly radiopaque stents (56% Palmaz-Schatz, 28% NIR, 10% Gianturco-Roubin, 6% Wallstent) expanded at high pressure (> = or 16 atm) were analyzed according to the conventional and stent excluded method. After stent implantation the reference diameter was 3.39 +/- 0.48 mm with conventional measurements and 3.02 +/- 0.45 mm with the stent excluded method (P < 0.05). The corresponding % diameter stenosis was 13 +/- 9 for the conventional technique and 1 +/- 13 for the stent excluded analysis (P < 0.05). The new approach to quantitative coronary analysis after stenting provides higher accuracy in reference diameter calculations and allows a more appropriate matching of stented segments with adjacent normal segments.

Mesh:

Year:  1997        PMID: 9096930     DOI: 10.1002/(sici)1097-0304(199704)40:4<343::aid-ccd3>3.0.co;2-9

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  5 in total

1.  A system for determination of 3D vessel tree centerlines from biplane images.

Authors:  K R Hoffmann; A Sen; L Lan; K G Chua; J Esthappan; M Mazzucco
Journal:  Int J Card Imaging       Date:  2000-10

2.  Variability of quantitative coronary angiography: an evaluation of on-site versus core laboratory analysis.

Authors:  Rasmus Moer; Anton W M van Weert; Yngvar Myreng; Per Mølstad
Journal:  Int J Cardiovasc Imaging       Date:  2003-12       Impact factor: 2.357

3.  Procedural and follow up results with a new balloon expandable stent in unselected lesions.

Authors:  C di Mario; B Reimers; Y Almagor; I Moussa; L Di Francesco; M Ferraro; M B Leon; K Richter; A Colombo
Journal:  Heart       Date:  1998-03       Impact factor: 5.994

4.  The use of drug eluting stents in single and multivessel disease: results from a single centre experience.

Authors:  G W Mikhail; F Airoldi; D Tavano; A Chieffo; R Rogacka; M Carlino; M Montorfano; G Sangiorgi; N Corvaja; I Michev; D Orlic; C Di Mario; A Colombo
Journal:  Heart       Date:  2004-09       Impact factor: 5.994

5.  Endoplasmic Reticulum Is Involved in Myocardial Injury in a Miniature Swine Model of Coronary Artery Stenosis Exposed to Acceleration-Associated Stress.

Authors:  Haitao Zhang; Meng Chai; Chaozhong Liu; Jinjin Sun; Congchun Huang; Xinya Yu; Yi Tian; Huilan Luo
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.