Literature DB >> 14686591

Implantable telemeter for long-term electroneurographic recordings in animals and humans.

N de N Donaldson1, L Zhou, T A Perkins, M Munih, M Haugland, T Sinkjaer.   

Abstract

A system is described that amplifies an electroneurographic signal (ENG) from a tripolar electrode nerve cuff and transmits it from the implanted amplifier to an external drive box. The output was raw ENG, bandpass filtered from 800 to 8000 Hz. The implant was powered by radio-frequency induction and operated for coil-to-coil separations up to 30 mm. The testing and performance of the system is described. The input-referred noise was never more than 1 microV RMS, and, at some positions of the radio-frequency field, was 0.7 microV, close to the expected value for the amplifier used. The common-mode rejection ratio (CMRR) depended on the impedance imbalance from the cuff and the length of input cable. Devices with a short cable and low source impedance had CMRR of 84 dB, but, with 31 cm of cable and a real cuff, the CMRR fell to 66 dB. Recovery from a stimulus artifact took 5 ms. The responses of the cuff to external potential gradients and to common-mode signals are described theoretically or by simulation. The devices are available for use in neuroprosthetic or neurophysiological research.

Entities:  

Mesh:

Year:  2003        PMID: 14686591     DOI: 10.1007/BF02349973

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  19 in total

1.  Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man.

Authors:  M Haugland; A Lickel; J Haase; T Sinkjaer
Journal:  IEEE Trans Rehabil Eng       Date:  1999-06

2.  The effect of nerve cuff geometry on interference reduction: a study by computer modeling.

Authors:  M Rahal; J Taylor; N Donaldson
Journal:  IEEE Trans Biomed Eng       Date:  2000-01       Impact factor: 4.538

3.  Effect of the metallic seal of a hermetic enclosure on the induction of power to an implant.

Authors:  N D Donaldson
Journal:  Med Biol Eng Comput       Date:  1992-01       Impact factor: 2.602

4.  Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes.

Authors:  B Upshaw; T Sinkjaer
Journal:  IEEE Trans Rehabil Eng       Date:  1998-06

5.  Analysis of bladder related nerve cuff electrode recordings from preganglionic pelvic nerve and sacral roots in pigs.

Authors:  S Jezernik; J G Wen; N J Rijkhoff; J C Djurhuus; T Sinkjaer
Journal:  J Urol       Date:  2000-04       Impact factor: 7.450

6.  The Craggs connector: a termination for Cooper cable.

Authors:  P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

7.  Morphognostic coils: a technique for transmitting several nearfield radio signals through the same space.

Authors:  N D de Donaldson
Journal:  Med Biol Eng Comput       Date:  1979-03       Impact factor: 2.602

8.  Analysis of resonant coupled coils in the design of radio frequency transcutaneous links.

Authors:  N D Donaldson; T A Perkins
Journal:  Med Biol Eng Comput       Date:  1983-09       Impact factor: 2.602

9.  The Cooper cable: an implantable multiconductor cable for neurological prostheses.

Authors:  P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

10.  Vagal stimulation reduces the severity of maximal electroshock seizures in intact rats: use of a cuff electrode for stimulating and recording.

Authors:  J W Woodbury; D M Woodbury
Journal:  Pacing Clin Electrophysiol       Date:  1991-01       Impact factor: 1.976

View more
  4 in total

1.  Noise from implantable Cooper cable.

Authors:  V Carrington; L Zhou; N Donaldson
Journal:  Med Biol Eng Comput       Date:  2005-09       Impact factor: 2.602

2.  Noise and selectivity of velocity-selective multi-electrode nerve cuffs.

Authors:  N Donaldson; R Rieger; M Schuettler; J Taylor
Journal:  Med Biol Eng Comput       Date:  2008-08-12       Impact factor: 2.602

3.  Design of a cybernetic hand for perception and action.

Authors:  M C Carrozza; G Cappiello; S Micera; B B Edin; L Beccai; C Cipriani
Journal:  Biol Cybern       Date:  2006-12-06       Impact factor: 2.086

4.  An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.

Authors:  Ahnsei Shon; Jun-Uk Chu; Jiuk Jung; Hyungmin Kim; Inchan Youn
Journal:  Sensors (Basel)       Date:  2017-12-21       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.