Literature DB >> 6633013

Analysis of resonant coupled coils in the design of radio frequency transcutaneous links.

N D Donaldson, T A Perkins.   

Abstract

Mesh:

Year:  1983        PMID: 6633013     DOI: 10.1007/BF02442388

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  5 in total

1.  Design of radio-frequency powered coils for implant instruments.

Authors:  W H Ko; S P Liang; C D Fung
Journal:  Med Biol Eng Comput       Date:  1977-11       Impact factor: 2.602

2.  Mutual inductance of air-cored coils: effect on design of radio-frequency coupled implants.

Authors:  F C Flack; E D James; D M Schlapp
Journal:  Med Biol Eng       Date:  1971-03

3.  Morphognostic coils: a technique for transmitting several nearfield radio signals through the same space.

Authors:  N D de Donaldson
Journal:  Med Biol Eng Comput       Date:  1979-03       Impact factor: 2.602

4.  Theoretical design and implementation of a transcutaneous, multichannel stimulator for neural prosthesis applications.

Authors:  I C Forster
Journal:  J Biomed Eng       Date:  1981-04

Review 5.  Hyperthermia production for cancer therapy: a review of fundamentals and methods.

Authors:  D A Christensen; C H Durney
Journal:  J Microw Power       Date:  1981-06
  5 in total
  19 in total

Review 1.  Theory and applications of biotelemetry.

Authors:  Nihal Fatma Güler; Elif Derya Ubeyli
Journal:  J Med Syst       Date:  2002-04       Impact factor: 4.460

2.  Implantable telemeter for long-term electroneurographic recordings in animals and humans.

Authors:  N de N Donaldson; L Zhou; T A Perkins; M Munih; M Haugland; T Sinkjaer
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

3.  The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission.

Authors:  Mehdi Kiani; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst I Regul Pap       Date:  2012-09       Impact factor: 3.605

4.  Class E driver for transcutaneous power and data link for implanted electronic devices.

Authors:  P R Troyk; M A Schwan
Journal:  Med Biol Eng Comput       Date:  1992-01       Impact factor: 2.602

5.  Effect of the metallic seal of a hermetic enclosure on the induction of power to an implant.

Authors:  N D Donaldson
Journal:  Med Biol Eng Comput       Date:  1992-01       Impact factor: 2.602

6.  Geometry-based optimization of radio-frequency coils for powering neuroprosthetic implants.

Authors:  Jungsuk Kim; Eric Basham; Kenneth D Pedrotti
Journal:  Med Biol Eng Comput       Date:  2012-10-21       Impact factor: 2.602

7.  Transcutaneous RF-powered implantable minipump driven by a class-E transmitter.

Authors:  William H Moore; Daniel P Holschneider; Tina K Givrad; Jean-Michel I Maarek
Journal:  IEEE Trans Biomed Eng       Date:  2006-08       Impact factor: 4.538

8.  Inductive RF link for an auditory prosthesis.

Authors:  P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1987-05       Impact factor: 2.602

9.  Passive signalling via inductive coupling.

Authors:  N D Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-03       Impact factor: 2.602

10.  When are actively balanced biphasic ('Lilly') stimulating pulses necessary in a neurological prosthesis? II. pH changes; noxious products; electrode corrosion; discussion.

Authors:  N D Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-01       Impact factor: 2.602