Noise from implantable Cooper cable.

V Carrington1, L Zhou, N Donaldson.   

Abstract

Cooper cable is made for implanted devices, usually for connection to stimulating electrodes. An experiment has been performed to see whether these cables would be satisfactory for recording electroneurogram (ENG) signals from cuffs. Four cables were subjected to continuous flexion at 2 Hz while submerged in saline. The cables were connected to a low-noise amplifier, and the noise was measured using a spectrum analyser. These cables had not fractured after 184 million flexions, and the noise in the neural band (500-5000 Hz) had not increased owing to age. Noise in the ENG band increased by less than 3 dB owing to the motion. A fifth, worn cable did fail during the experiment, the conductors becoming exposed to the saline, but this was only apparent by extra noise when the cable was in motion. After 184 million flexions, the four cables were given a more severe test: instead of being connected to the amplifier reference node, two of the four cores of each cable were connected to 18V batteries. Two of the cables were then noisier, but only when in motion, presumably because of leakage between cores. Cooper cables are excellent for transmitting neural signals alone; transmission in one cable of neural signals and power supplies should be avoided if possible.

Entities:  

Mesh:

Year:  2005        PMID: 16411634     DOI: 10.1007/bf02351035

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Cuff electrodes for long-term recording of natural sensory information.

Authors:  J J Struijk; M Thomsen; J O Larsen; T Sinkjaer
Journal:  IEEE Eng Med Biol Mag       Date:  1999 May-Jun

2.  A reconnectable multiway implantable connector.

Authors:  D N Rushton; A M Tromans; N de N Donaldson
Journal:  Med Eng Phys       Date:  2002-12       Impact factor: 2.242

3.  Implantable telemeter for long-term electroneurographic recordings in animals and humans.

Authors:  N de N Donaldson; L Zhou; T A Perkins; M Munih; M Haugland; T Sinkjaer
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

4.  The Craggs connector: a termination for Cooper cable.

Authors:  P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

5.  The first 500 sacral anterior root stimulators: implant failures and their repair.

Authors:  G S Brindley
Journal:  Paraplegia       Date:  1995-01

6.  The Cooper cable: an implantable multiconductor cable for neurological prostheses.

Authors:  P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.