Literature DB >> 20981274

High-resolution coregistered intravascular imaging with integrated ultrasound and optical coherence tomography probe.

Xiang Li, Jiechen Yin, Changhong Hu, Qifa Zhou, K Kirk Shung, Zhongping Chen.   

Abstract

We report an integrated ultrasound (US) and optical coherence tomography (OCT) probe and system for intravascular imaging. The dual-function probe is based on a 50 MHz focused ring US transducer, with a centric hole for mounting OCT probe. The coaxial US and light beams are steered by a 45° mirror to enable coregistered US∕OCT imaging simultaneously. Lateral resolution of US is improved due to focused ultrasonic beam. Mirror effects on US were investigated and invitro imaging of a rabbit aorta has been carried out. The combined US-OCT system demonstrated high resolution in visualizing superficial arterial structures while retaining deep penetration of ultrasonic imaging.

Entities:  

Year:  2010        PMID: 20981274      PMCID: PMC2962660          DOI: 10.1063/1.3493659

Source DB:  PubMed          Journal:  Appl Phys Lett        ISSN: 0003-6951            Impact factor:   3.791


  10 in total

Review 1.  Advances in ultrasound biomicroscopy.

Authors:  F S Foster; C J Pavlin; K A Harasiewicz; D A Christopher; D H Turnbull
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

2.  Diagnostic accuracy of optical coherence tomography and integrated backscatter intravascular ultrasound images for tissue characterization of human coronary plaques.

Authors:  Masanori Kawasaki; Brett E Bouma; Jason Bressner; Stuart L Houser; Seemantini K Nadkarni; Briain D MacNeill; Ik-Kyung Jang; Hisayoshi Fujiwara; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2006-06-09       Impact factor: 24.094

Review 3.  Optical coherence tomography for imaging the vulnerable plaque.

Authors:  Guillermo J Tearney; Ik-Kyung Jang; Brett E Bouma
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

4.  Real-time swept source optical coherence tomography imaging of the human airway using a microelectromechanical system endoscope and digital signal processor.

Authors:  Jianping Su; Jun Zhang; Lingfeng Yu; Henri G Colt; Matthew Brenner; Zhongping Chen
Journal:  J Biomed Opt       Date:  2008 May-Jun       Impact factor: 3.170

5.  Feasibility of combined use of intravascular ultrasound radiofrequency data analysis and optical coherence tomography for detecting thin-cap fibroatheroma.

Authors:  Takahiro Sawada; Junya Shite; Hector M Garcia-Garcia; Toshiro Shinke; Satoshi Watanabe; Hiromasa Otake; Daisuke Matsumoto; Yusuke Tanino; Daisuke Ogasawara; Hiroyuki Kawamori; Hiroki Kato; Naoki Miyoshi; Mitsuhiro Yokoyama; Patrick W Serruys; Ken-ichi Hirata
Journal:  Eur Heart J       Date:  2008-04-07       Impact factor: 29.983

6.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

7.  Integrated intravascular optical coherence tomography ultrasound imaging system.

Authors:  Jiechen Yin; Hao-Chung Yang; Xiang Li; Jun Zhang; Qifa Zhou; Changhong Hu; K Kirk Shung; Zhongping Chen
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

8.  Assessment of coronary plaque with optical coherence tomography and high-frequency ultrasound.

Authors:  P Patwari; N J Weissman; S A Boppart; C Jesser; D Stamper; J G Fujimoto; M E Brezinski
Journal:  Am J Cardiol       Date:  2000-03-01       Impact factor: 2.778

Review 9.  The thin-cap fibroatheroma: a type of vulnerable plaque: the major precursor lesion to acute coronary syndromes.

Authors:  F D Kolodgie; A P Burke; A Farb; H K Gold; J Yuan; J Narula; A V Finn; R Virmani
Journal:  Curr Opin Cardiol       Date:  2001-09       Impact factor: 2.161

10.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

  10 in total
  23 in total

1.  Integrated ultrasound and photoacoustic probe for co-registered intravascular imaging.

Authors:  Wei Wei; Xiang Li; Qifa Zhou; K Kirk Shung; Zhongping Chen
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

2.  Electrochemical impedance spectroscopy to characterize inflammatory atherosclerotic plaques.

Authors:  Fei Yu; Xiaohu Dai; Tyler Beebe; Tzung Hsiai
Journal:  Biosens Bioelectron       Date:  2011-09-16       Impact factor: 10.618

Review 3.  Intravascular imaging of vulnerable coronary plaque: current and future concepts.

Authors:  Rishi Puri; Matthew I Worthley; Stephen J Nicholls
Journal:  Nat Rev Cardiol       Date:  2011-01-25       Impact factor: 32.419

4.  Novel combined miniature optical coherence tomography ultrasound probe for in vivo intravascular imaging.

Authors:  Jiechen Yin; Xiang Li; Joe Jing; Jiawen Li; David Mukai; Sari Mahon; Ahmad Edris; Khiet Hoang; K Kirk Shung; Matthew Brenner; Jagat Narula; Qifa Zhou; Zhongping Chen
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

5.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

6.  Intravascular photoacoustic imaging at 35 and 80 MHz.

Authors:  Xiang Li; Wei Wei; Qifa Zhou; K Kirk Shung; Zhongping Chen
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

7.  Multi-frequency intravascular ultrasound (IVUS) imaging.

Authors:  Teng Ma; Mingyue Yu; Jiawen Li; Chelsea E Munding; Zeyu Chen; Chunlong Fei; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

Review 8.  Intravascular optical imaging technology for investigating the coronary artery.

Authors:  Melissa J Suter; Seemantini K Nadkarni; Giora Weisz; Atsushi Tanaka; Farouc A Jaffer; Brett E Bouma; Guillermo J Tearney
Journal:  JACC Cardiovasc Imaging       Date:  2011-09

9.  Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization.

Authors:  Xiang Li; Jiawen Li; Joe Jing; Teng Ma; Shanshan Liang; Jun Zhang; Dilbahar Mohar; Aidan Raney; Sari Mahon; Matthew Brenner; Pranav Patel; K Kirk Shung; Qifa Zhou; Zhongping Chen
Journal:  IEEE J Sel Top Quantum Electron       Date:  2014-03       Impact factor: 4.544

10.  High speed intravascular photoacoustic imaging with fast optical parametric oscillator laser at 1.7 μm.

Authors:  Zhonglie Piao; Teng Ma; Jiawen Li; Maximilian T Wiedmann; Shenghai Huang; Mingyue Yu; K Kirk Shung; Qifa Zhou; Chang-Seok Kim; Zhongping Chen
Journal:  Appl Phys Lett       Date:  2015-08-26       Impact factor: 3.791

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.