Design of matching layers for high-frequency ultrasonic transducers.

Chunlong Fei, Jianguo Ma, Chi Tat Chiu1, Jay A Williams1, Wayne Fong1, Zeyu Chen1, BenPeng Zhu1, Rui Xiong2, Jing Shi2, Tzung K Hsiai, K Kirk Shung1, Qifa Zhou1.   

Abstract

Matching the acoustic impedance of high-frequency (≥100 MHz) ultrasound transducers to an aqueous loading medium remains a challenge for fabricating high-frequency transducers. The traditional matching layer design has been problematic to establish high matching performance given requirements on both specific acoustic impedance and precise thickness. Based on both mass-spring scheme and microwave matching network analysis, we interfaced metal-polymer layers for the matching effects. Both methods hold promises for guiding the metal-polymer matching layer design. A 100 MHz LiNbO3 transducer was fabricated to validate the performance of the both matching layer designs. In the pulse-echo experiment, the transducer echo amplitude increased by 84.4% and its -6dB bandwidth increased from 30.2% to 58.3% comparing to the non-matched condition, demonstrating that the matching layer design method is effective for developing high-frequency ultrasonic transducers.

Entities:  

Year:  2015        PMID: 26445518      PMCID: PMC4583513          DOI: 10.1063/1.4931703

Source DB:  PubMed          Journal:  Appl Phys Lett        ISSN: 0003-6951            Impact factor:   3.791


  11 in total

1.  Novel multi-layer polymer-metal structures for use in ultrasonic transducer impedance matching and backing absorber applications.

Authors:  Minoru Toda; Mitchell Thompson
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-12       Impact factor: 2.725

2.  Development of a 35-MHz piezo-composite ultrasound array for medical imaging.

Authors:  Jonathan M Cannata; Jay A Williams; Qifa Zhou; Timothy A Ritter; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-01       Impact factor: 2.725

3.  Fabrication and performance of a miniaturized 64-element high-frequency endoscopic phased array.

Authors:  Andre Bezanson; Rob Adamson; Jeremy Brown
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

4.  Mass-spring matching layers for high-frequency ultrasound transducers: a new technique using vacuum deposition.

Authors:  Jeremy Brown; Srikanta Sharma; Jeff Leadbetter; Sandy Cochran; Rob Adamson
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-11       Impact factor: 2.725

5.  An acoustic filter based on layered structure.

Authors:  Jianguo Ma; Michael B Steer; Xiaoning Jiang
Journal:  Appl Phys Lett       Date:  2015-03-16       Impact factor: 3.791

6.  Piezoelectric films for high frequency ultrasonic transducers in biomedical applications.

Authors:  Qifa Zhou; Sienting Lau; Dawei Wu; K Kirk Shung
Journal:  Prog Mater Sci       Date:  2011-02

7.  Focused high frequency needle transducer for ultrasonic imaging and trapping.

Authors:  Hsiu-Sheng Hsu; Fan Zheng; Ying Li; Changyang Lee; Qifa Zhou; K Kirk Shung
Journal:  Appl Phys Lett       Date:  2012-07-11       Impact factor: 3.791

8.  Targeted cell immobilization by ultrasound microbeam.

Authors:  Jungwoo Lee; Changyang Lee; Hyung Ham Kim; Anette Jakob; Robert Lemor; Shia-Yen Teh; Abraham Lee; Koping Kirk Shung
Journal:  Biotechnol Bioeng       Date:  2011-02-19       Impact factor: 4.530

9.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

10.  Ultrahigh frequency lensless ultrasonic transducers for acoustic tweezers application.

Authors:  Kwok Ho Lam; Hsiu-Sheng Hsu; Ying Li; Changyang Lee; Anderson Lin; Qifa Zhou; Eun Sok Kim; Kirk Koping Shung
Journal:  Biotechnol Bioeng       Date:  2012-10-16       Impact factor: 4.530

View more
  6 in total

1.  Design and Micro-Fabrication of Focused High-Frequency Needle Transducers for Medical Imaging.

Authors:  Thanh Phuoc Nguyen; Jaeyeop Choi; Van Tu Nguyen; Sudip Mondal; Ngoc Thang Bui; Dinh Dat Vu; Sumin Park; Junghwan Oh
Journal:  Sensors (Basel)       Date:  2022-05-15       Impact factor: 3.847

Review 2.  Optical ultrasound sensors for photoacoustic imaging: a narrative review.

Authors:  Bo Fu; Yuan Cheng; Ce Shang; Jing Li; Gang Wang; Chenghong Zhang; Jingxuan Sun; Jianguo Ma; Xunming Ji; Boqu He
Journal:  Quant Imaging Med Surg       Date:  2022-02

3.  Particle Swarm Optimization Algorithm-Based Design Method for Ultrasonic Transducers.

Authors:  Dongdong Chen; Jianxin Zhao; Chunlong Fei; Di Li; Yuanbo Zhu; Zhaoxi Li; Rong Guo; Lifei Lou; Wei Feng; Yintang Yang
Journal:  Micromachines (Basel)       Date:  2020-07-23       Impact factor: 2.891

4.  Solidly mounted resonator sensor for biomolecule detections.

Authors:  Chengzhang Han; Xia Wang; Qiuling Zhao; Lihua Teng; Shuaiyi Zhang; Hao Lv; Jing Liu; Haoran Ma; Yanping Wang
Journal:  RSC Adv       Date:  2019-07-09       Impact factor: 4.036

5.  FPCB as an Acoustic Matching Layer for 1D Linear Ultrasound Transducer Arrays.

Authors:  Taemin Lee; Joontaek Jung; Sang-Mok Lee; Jongcheol Park; Jae-Hyeong Park; Kyung-Wook Paik; Hyunjoo J Lee
Journal:  Sensors (Basel)       Date:  2022-07-25       Impact factor: 3.847

6.  Minimizing the Programming Power of Phase Change Memory by Using Graphene Nanoribbon Edge-Contact.

Authors:  Xiujun Wang; Sannian Song; Haomin Wang; Tianqi Guo; Yuan Xue; Ruobing Wang; HuiShan Wang; Lingxiu Chen; Chengxin Jiang; Chen Chen; Zhiyuan Shi; Tianru Wu; Wenxiong Song; Sifan Zhang; Kenji Watanabe; Takashi Taniguchi; Zhitang Song; Xiaoming Xie
Journal:  Adv Sci (Weinh)       Date:  2022-07-18       Impact factor: 17.521

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.