Literature DB >> 14659449

Determination of levofloxacin in plasma, bronchoalveolar lavage and bone tissues by high-performance liquid chromatography with ultraviolet detection using a fully automated extraction method.

S Djabarouti1, E Boselli, B Allaouchiche, B Ba, A T Nguyen, J B Gordien, J M Bernadou, M C Saux, D Breilh.   

Abstract

The aim of this study was to develop a specific and sensitive high-performance liquid chromatographic (HPLC) assay for the determination of levofloxacin in human plasma, bronchoalveolar lavage and bone tissues. The sample extraction was based on a fully automated liquid-solid extraction with an OASIS cartridge. The method used ultraviolet detection set at a wavelength of 299 nm and a separation with a Supelcosil ABZ+ column. The assay has been found linear over the concentration range 0.25-25 microg/ml for levofloxacin in plasma, 1-6 microg/ml in bronchoalveolar lavage and 0.5-10 microg/g for bone tissues and it provided good validation data for accuracy and precision. The assay will be applied to determine the penetration of levofloxacin in human bronchoalveolar lavage (BAL) and bone tissues during pharmacokinetic steady state.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14659449     DOI: 10.1016/j.jchromb.2003.10.031

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  10 in total

1.  Adjuvant arthritis-induced changes on ampicillin binding in serum and tissues under the influence of non-steroidal anti-inflammatory drugs in rats.

Authors:  E Tigka; I Daskala; G Rallis; S Anagnostopoulou; C Tesseromatis
Journal:  Eur J Drug Metab Pharmacokinet       Date:  2005 Oct-Dec       Impact factor: 2.441

2.  Pharmacokinetics of intravenous levofloxacin administered at 750 milligrams in obese adults.

Authors:  Aaron M Cook; Craig Martin; Val R Adams; R Scott Morehead
Journal:  Antimicrob Agents Chemother       Date:  2011-05-16       Impact factor: 5.191

3.  Simultaneous determination of the combined drugs of ceftriaxone sodium, metronidazole, and levofloxacin in human urine by high-performance liquid chromatography.

Authors:  Hanwen Sun; Hongliu Wang; Xusheng Ge
Journal:  J Clin Lab Anal       Date:  2012-11       Impact factor: 2.352

Review 4.  Penetration of antibacterials into bone: pharmacokinetic, pharmacodynamic and bioanalytical considerations.

Authors:  Cornelia B Landersdorfer; Jürgen B Bulitta; Martina Kinzig; Ulrike Holzgrabe; Fritz Sörgel
Journal:  Clin Pharmacokinet       Date:  2009       Impact factor: 6.447

5.  Glycopeptide bone penetration in patients with septic pseudoarthrosis of the tibia.

Authors:  Silvia Garazzino; Alessandro Aprato; Lorena Baietto; Antonio D'Avolio; Agostino Maiello; Francesco Giuseppe De Rosa; Domenico Aloj; Marco Siccardi; Antonio Biasibetti; Alessandro Massè; Giovanni Di Perri
Journal:  Clin Pharmacokinet       Date:  2008       Impact factor: 6.447

6.  Bone penetration of amoxicillin and clavulanic acid evaluated by population pharmacokinetics and Monte Carlo simulation.

Authors:  Cornelia B Landersdorfer; Martina Kinzig; Jürgen B Bulitta; Friedrich F Hennig; Ulrike Holzgrabe; Fritz Sörgel; Johannes Gusinde
Journal:  Antimicrob Agents Chemother       Date:  2009-03-23       Impact factor: 5.191

7.  Levofloxacin loaded mesoporous silica microspheres/nano-hydroxyapatite/polyurethane composite scaffold for the treatment of chronic osteomyelitis with bone defects.

Authors:  Qi Wang; Cheng Chen; Wen Liu; Xiaoqiang He; Nian Zhou; Dongli Zhang; Hongchen Gu; Jidong Li; Jiaxing Jiang; Wei Huang
Journal:  Sci Rep       Date:  2017-02-02       Impact factor: 4.379

Review 8.  Analytical Methods for Determining Third and Fourth Generation Fluoroquinolones: A Review.

Authors:  Andrzej Czyrski
Journal:  Chromatographia       Date:  2016-12-23       Impact factor: 2.044

9.  CL sensitisation of tris-(bipyridyl) ruthenium (II) - cerium (IV) reaction system by AgNPs for determination of GFX.

Authors:  Saikh Mohammad Wabaidur; Seikh M Alam
Journal:  IET Nanobiotechnol       Date:  2018-09       Impact factor: 1.847

10.  Fiberoptic-Coupled Spectrofluorometer with Array Detection as a Process Analytical Chemistry Tool for Continuous Flow Monitoring of Fluoroquinolone Antibiotics.

Authors:  Nader Shokoufi; Maryam Vosough; Mona Rahimzadegan-Asl; Atefeh Abbasi-Ahd; Mahsa Khatibeghdami
Journal:  Int J Anal Chem       Date:  2020-02-07       Impact factor: 1.885

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.