Literature DB >> 14646710

Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips.

Georgios Digas1, Johan Kärrholm, Jonas Thanner, Henrik Malchau, Peter Herberts.   

Abstract

Highly cross-linked polyethylene (PE) has been introduced as an alternative bearing material in total hip arthroplasty (THA) because of high wear resistance in laboratory tests but the clinical experience of this material is limited. We evaluated a highly cross-linked PE (warm irradiated adiabatic melting, absorbed dose, 95 kGy) in a randomized study of cemented THAs. Cups of the same design but made of conventionally gamma irradiated PE (absorbed dose, 25-40 kGy) constituted the control group. Sixty-one hips (30 women, 30 men) with a median age of 55 years (range, 35-70 years) were included. All patients received a Spectron stem with 28-mm CoCr head. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured with the patient in the supine position from the first postoperative week, whereas examinations done with the patient standing were initiated 3 months after the operation. Dual x-ray absorptiometry and conventional radiography were used to evaluate the bone mineral density and the radiolucencies around the acetabular component. Fifty-two patients (53 hips; 25 highly cross-linked, 28 control) have been followed up for 2 years. At the 2-year followup, the highly cross-linked cups showed 50% reduction of proximal wear compared with the control group, when the patients were studied standing. When evaluated supine, the difference in proximal wear did not reach significance. The migration of the socket, the relative changes of periprosthetic bone mineral density, and the progression of radiolucencies between the immediately postoperative followup and 2-year followup did not differ. Highly cross-linked PE showed increase resistance to wear. Different mechanical properties of the two types of PE studied did not alter the performance of the cup in terms of fixation, periprosthetic bone loss, and radiographic appearance. However, the followup is short and these results are preliminary.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14646710     DOI: 10.1097/01.blo.0000096802.78689.45

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Precision and accuracy measurement of radiostereometric analysis applied to movement of the sacroiliac joint.

Authors:  Thomas J Kibsgård; Olav Røise; Britt Stuge; Stephan M Röhrl
Journal:  Clin Orthop Relat Res       Date:  2012-06-14       Impact factor: 4.176

3.  Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Authors:  Adolph V Lombardi; Michael D Skeels; Keith R Berend; Joanne B Adams; Orlando J Franchi
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  Mechanical properties of retrieved highly cross-linked crossfire liners after short-term implantation.

Authors:  Steven M Kurtz; William Hozack; Joseph Turner; James Purtill; Daniel MacDonald; Peter Sharkey; Javad Parvizi; Michael Manley; Richard Rothman
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

5.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

6.  Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova
Journal:  Int Orthop       Date:  2009-02-13       Impact factor: 3.075

7.  Percutaneous epiphysiodesis in the proximal tibia by a single-portal approach: evaluation by radiostereometric analysis.

Authors:  Joachim Horn; Ragnhild Beate Gunderson; Anders Wensaas; Harald Steen
Journal:  J Child Orthop       Date:  2013-06-12       Impact factor: 1.548

8.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

9.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

10.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.