[Precision in standardized Iso-C-Arm based navigated boring of the proximal femur].

M Arand1, M Schempf, L Kinzl, T Fleiter, D Pless, F Gebhard.   

Abstract

C-arm navigation is a new tool in computer assisted surgery. The aim of this study is to evaluate the accuracy of Iso-C-arm based drill holes in the proximal femur. In nine artificial proximal femura, two holes with an angle of 135 degrees and 100 degrees in relation to the shaft axis were drilled in the direction of the femoral head. The defined target of the 3.2 mm drillings was a 4 mm steel ball, which had previously been placed and fixed at the cranial center of the femoral head. All the drillings were standardized with a navigated drilling machine fixed to a frame which only allowed movement of the system in the direction of the drill. During navigation the positions of the drill before commencement and at the deepest point of the canal were recorded. After drilling all specimens were evaluated by CT, and the coordinates of the center of the start and the end of the drilled hole and the center of the ball were determined. Using vector calculation, the smallest distance between the straight line, defined by the center of the starting point and the end point of the drill hole, and the center of the ball was calculated. Additionally, the coordinates of the intersection between the perpendicular to the center of the ball and the straight line were determined (xv, yv, zv), to evaluate the direction of misplacement of the drilled canal in relation to the target. For the 135 degrees drill holes, a median of 2.5 mm for the smallest distance between the straight line, given by the center of the start and the end of the hole, and the center of the ball was investigated (range 1.6-3.7 mm). For the 100 degrees holes the median was 3.1 mm (range 1.8-4.2 mm). The main plane of deviation in all of the 135 degrees holes was posteriorly, whereas in the 100 degrees holes posterior deviation occurred in four cases, cranial in three cases, and in one case each caudal and anterior deviation occurred. In our opinion, the accuracy of fluoroscopy based navigation applied in the region of the proximal femur is sufficient and reproducible. This technique can be used for implant placement at the proximal femur in the future.

Entities:  

Mesh:

Year:  2001        PMID: 11803721     DOI: 10.1007/s001130170007

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  5 in total

1.  [Navigated osteosynthesis of the proximal femur. An experimental study].

Authors:  T Hüfner; M Kfuri; D Kendoff; M Richter; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  [Precision of navigation-assisted surgery of the thoracic and lumbar spine].

Authors:  M Arand; M Schempf; D Hebold; S Teller; L Kinzl; F Gebhard
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  [Navigated drilling for femoral head necrosis. Experimental and clinical results].

Authors:  J Beckmann; M Tingart; L Perlick; C Lüring; J Grifka; S Anders
Journal:  Orthopade       Date:  2007-05       Impact factor: 1.087

4.  [Precision of guidewire placement--can it be improved by applying the new, isocentric aiming principle?].

Authors:  N Suhm; P Toggwiler; M Hänni; V Quarz; A Appelt
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

5.  [A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation].

Authors:  D Kendoff; T Hüfner; M Citak; C Maier; F Wesemeier; A Pearle; C Krettek
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.