Alain Combes1, Florence Arnoult, Jean-Louis Trouillet. 1. Réanimation Médicale,Institut de Cardiologie, AP-HP, Hôpital Pitié-Salpêtrière, 47 Boulevard de l'Hôpital, 75013 Paris, France. alain.combes@psl.ap-hop-paris.fr
Abstract
OBJECTIVE: Earlier reports suggested that transthoracic (TTE) determination of the ratio of mitral inflow E wave velocity to early diastolic mitral annulus velocity (E/E') measured by tissue Doppler imaging (TDI) closely approximates PAOP in cardiac patients. However, the value of E/E' for PAOP assessment in ICU patients has not been evaluated. This study assessed whether the E/E' ratio provides an accurate estimation of pulmonary artery occlusion pressure (PAOP) in mechanically ventilated ICU patients. DESIGN AND SETTING: Prospective, open, clinical study in the ICU of a university hospital. PATIENTS: Twenty-three consecutive mechanically ventilated patients. INTERVENTIONS: Volume expansion in 14 patients. MEASUREMENTS AND RESULTS: Doppler TTE or TEE mitral inflow and TDI mitral annulus velocities were determined and compared with PAOP measured using a Swan-Ganz catheter. Of all the Doppler variables studied the best correlations were observed between PAOP and the lateral (r=0.84) and medial (r=0.76) annulus E/E' ratio and remained highly significant when the analysis was restricted to TEE (r=0.91 and 0.86) or TTE (r=0.73 and 0.61). The sensitivities and specificities of estimating PAOP at 15 mmHg or higher were, respectively, 86% and 81% for lateral E/E' above 7.5 and 76% and 80% for medial E/E' above 9. PAOP changes after volume expansion (700+/-230 ml) were limited and accurately assessed by repeated E/E' determinations. CONCLUSIONS: In mechanically ventilated ICU patients TTE or TEE E/E' determinations using TDI closely approximate PAOP.
OBJECTIVE: Earlier reports suggested that transthoracic (TTE) determination of the ratio of mitral inflow E wave velocity to early diastolic mitral annulus velocity (E/E') measured by tissue Doppler imaging (TDI) closely approximates PAOP in cardiac patients. However, the value of E/E' for PAOP assessment in ICU patients has not been evaluated. This study assessed whether the E/E' ratio provides an accurate estimation of pulmonary artery occlusion pressure (PAOP) in mechanically ventilated ICU patients. DESIGN AND SETTING: Prospective, open, clinical study in the ICU of a university hospital. PATIENTS: Twenty-three consecutive mechanically ventilated patients. INTERVENTIONS: Volume expansion in 14 patients. MEASUREMENTS AND RESULTS: Doppler TTE or TEE mitral inflow and TDI mitral annulus velocities were determined and compared with PAOP measured using a Swan-Ganz catheter. Of all the Doppler variables studied the best correlations were observed between PAOP and the lateral (r=0.84) and medial (r=0.76) annulus E/E' ratio and remained highly significant when the analysis was restricted to TEE (r=0.91 and 0.86) or TTE (r=0.73 and 0.61). The sensitivities and specificities of estimating PAOP at 15 mmHg or higher were, respectively, 86% and 81% for lateral E/E' above 7.5 and 76% and 80% for medial E/E' above 9. PAOP changes after volume expansion (700+/-230 ml) were limited and accurately assessed by repeated E/E' determinations. CONCLUSIONS: In mechanically ventilated ICU patients TTE or TEE E/E' determinations using TDI closely approximate PAOP.
Authors: S R Ommen; R A Nishimura; C P Appleton; F A Miller; J K Oh; M M Redfield; A J Tajik Journal: Circulation Date: 2000-10-10 Impact factor: 29.690
Authors: G R Bernard; G Sopko; F Cerra; R Demling; H Edmunds; S Kaplan; L Kessler; H Masur; P Parsons; D Shure; C Webb; H Weidemann; G Weinmann; D Williams Journal: JAMA Date: 2000-05-17 Impact factor: 56.272
Authors: D W Sohn; I H Chai; D J Lee; H C Kim; H S Kim; B H Oh; M M Lee; Y B Park; Y S Choi; J D Seo; Y W Lee Journal: J Am Coll Cardiol Date: 1997-08 Impact factor: 24.094
Authors: Peter Andrews; Elie Azoulay; Massimo Antonelli; Laurent Brochard; Christian Brun-Buisson; Geoffrey Dobb; Jean-Yves Fagon; Herwig Gerlach; Johan Groeneveld; Jordi Mancebo; Philipp Metnitz; Stefano Nava; Jerome Pugin; Michael Pinsky; Peter Radermacher; Christian Richard; Robert Tasker; Benoit Vallet Journal: Intensive Care Med Date: 2005-01-28 Impact factor: 17.440
Authors: Vasilios E Papaioannou; Dimitrios A Stakos; Christos K Dragoumanis; Ioannis A Pneumatikos Journal: BMC Cardiovasc Disord Date: 2010-05-17 Impact factor: 2.298
Authors: Caroline Etchecopar-Chevreuil; Bruno François; Marc Clavel; Nicolas Pichon; Hervé Gastinne; Philippe Vignon Journal: Intensive Care Med Date: 2007-11-15 Impact factor: 17.440
Authors: Samuel M Brown; Joel E Pittman; Eliotte L Hirshberg; Jason P Jones; Michael J Lanspa; Kathryn G Kuttler; Sheldon E Litwin; Colin K Grissom Journal: Crit Ultrasound J Date: 2012-05-04