Literature DB >> 14628205

First use of a truly-hybrid X-ray/MR imaging system for guidance of brain biopsy.

R Fahrig1, G Heit, Z Wen, B L Daniel, K Butts, N J Pelc.   

Abstract

The use of a new hybrid imaging system for guidance of a brain biopsy is described. The system combines the strengths of MRI (soft-tissue contrast, arbitrary plane selection) with those of x-ray fluoroscopy (high-resolution real-time projection images, clear portrayal of bony structures) and allows switching between the imaging modalities without moving the patient. The biopsy was carried out using x-ray guidance for direction of the needle through the foramen ovale and MR guidance to target the soft-tissue lesion. Appropriate samples were acquired. The system could be particularly effective for guidance of those cases where motion, swelling, resection and other intra-operative anatomical changes cannot be accounted for using traditional stereotactic-based imaging approaches.

Entities:  

Mesh:

Year:  2003        PMID: 14628205     DOI: 10.1007/s00701-003-0138-7

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  7 in total

1.  Design optimization of MR-compatible rotating anode x-ray tubes for stable operation.

Authors:  Mihye Shin; Prasheel Lillaney; Waldo Hinshaw; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

2.  Closed bore XMR (CBXMR) systems for aortic valve replacement: investigation of rotating-anode x-ray tube heat loadability.

Authors:  John A Bracken; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

3.  Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

Authors:  Zhifei Wen; Rebecca Fahrig; Scott T Williams; Norbert J Pelc
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

4.  Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields.

Authors:  Prasheel Lillaney; Mihye Shin; Waldo Hinshaw; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization.

Authors:  Prasheel Lillaney; Mihye Shin; Steven M Conolly; Rebecca Fahrig
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

6.  Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system.

Authors:  Prasheel Lillaney; Mihye Shin; Waldo Hinshaw; N Robert Bennett; Norbert Pelc; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

7.  Use of perfluorocarbon nanoparticles for non-invasive multimodal cell tracking of human pancreatic islets.

Authors:  Brad P Barnett; Jesus Ruiz-Cabello; Partha Hota; Ronald Ouwerkerk; Michael J Shamblott; Cal Lauzon; Piotr Walczak; Wesley D Gilson; Vadappuram P Chacko; Dara L Kraitchman; Aravind Arepally; Jeff W M Bulte
Journal:  Contrast Media Mol Imaging       Date:  2011 Jul-Aug       Impact factor: 3.161

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.