Literature DB >> 14623781

Variations in radiation dose between the same model of multislice CT scanner at different hospitals.

C J Koller1, J P Eatough, A Bettridge.   

Abstract

The variation in exposure factors and patient dose, between seven centres using identical multislice CT scanners, was investigated for six standard examinations. Dose values were compared with each other and the relevant diagnostic reference level (DRL) for each examination. The range in weighted CT dose index (CTDI(w)) values between the seven centres was small for abdominal scans and head scans. For other scans however, such as functional endoscopic sinonasal surgery (FESS) the variations in CTDI(w) were as high as a factor of seven between the lowest and the highest values. At one centre a program of dose optimization had been undertaken and this centre had CTDI(w) values ranging from 3% to 64% lower than the average value for the seven centres. This demonstrates that significant dose reduction can be achieved through close collaboration between medical physicists, radiologists and radiographers.

Entities:  

Mesh:

Year:  2003        PMID: 14623781     DOI: 10.1259/bjr/33117342

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

Review 1.  Estimating radiation risk from computed tomography scanning.

Authors:  Vadim Fayngersh; Michael Passero
Journal:  Lung       Date:  2009-04-07       Impact factor: 2.584

2.  EANM guidelines for ventilation/perfusion scintigraphy : Part 2. Algorithms and clinical considerations for diagnosis of pulmonary emboli with V/P(SPECT) and MDCT.

Authors:  M Bajc; J B Neilly; M Miniati; C Schuemichen; M Meignan; B Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09       Impact factor: 9.236

3.  Diagnostic CT radiation and cancer induction.

Authors:  Paula J Richards; Jennifer George
Journal:  Skeletal Radiol       Date:  2010-05       Impact factor: 2.199

4.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel Long; Ryan Fisher; Chris Tien; Steven L Simon; Andre Bouville; Wesley E Bolch
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

Review 6.  Challenges in interventional radiology: the pregnant patient.

Authors:  Eunice K Moon; Weiping Wang; James S Newman; Maria Del Pilar Bayona-Molano
Journal:  Semin Intervent Radiol       Date:  2013-12       Impact factor: 1.513

7.  Standardized CT protocols and nomenclature: better, but not yet there.

Authors:  Sarabjeet Singh; Mannudeep K Kalra
Journal:  Pediatr Radiol       Date:  2014-10-11

8.  How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?

Authors:  Saravanabavaan Suntharalingam; Franz Ferdinand Stecker; Nika Guberina; Adrian Ringelstein; Thomas Schlosser; Jens Matthias Theysohn; Michael Forsting; Kai Nassenstein
Journal:  PLoS One       Date:  2016-04-06       Impact factor: 3.240

9.  Consensus Document of the Italian Association of Hospital Cardiologists (ANMCO), Italian Society of Pediatric Cardiology (SICP), and Italian Society of Gynaecologists and Obstetrics (SIGO): pregnancy and congenital heart diseases.

Authors:  Innocenzo Bianca; Giovanna Geraci; Michele Massimo Gulizia; Gabriele Egidy Assenza; Chiara Barone; Marcello Campisi; Annalisa Alaimo; Rachele Adorisio; Francesca Comoglio; Silvia Favilli; Gabriella Agnoletti; Maria Gabriella Carmina; Massimo Chessa; Berardo Sarubbi; Maurizio Mongiovì; Maria Giovanna Russo; Sebastiano Bianca; Giuseppe Canzone; Marco Bonvicini; Elsa Viora; Marco Poli
Journal:  Eur Heart J Suppl       Date:  2017-05-02       Impact factor: 1.803

10.  Universal sinus computed tomography protocol for diagnostic imaging and intraoperative navigation.

Authors:  Joseph M Hoxworth; Devyani Lal
Journal:  Allergy Rhinol (Providence)       Date:  2015-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.