A novel heart/trunk simulator for the study of electromagnetic interference with active implantable devices.

A Angeloni1, V Barbaro, P Bartolini, G Calcagnini, F Censi.   

Abstract

This paper describes a portable heart simulator for the study of electromagnetic interference with active implantable devices. The simulator consists of plexiglas box divided into three chambers simulating the left atrium and the ventricles, plus a lateral compartment for the implantable device. The box is linked to a laptop computer by an analogue-to-digital convertor board, and the three chambers are monitored and driven by dedicated hardware and software interfaces. Synthetic endocardial atrial and ventricle signals for 13 cardiac rhythms are stored in the computer. They are applied to the cardiac chambers by AgCl plates. Sensing electrodes are in the form of AgCl needles inserted in saline. The simulator was able to demonstrate the behaviour of three pacemakers tested in the absence and presence of electromagnetic interference, generated by mobile phones (European GSM 900 and 1800 MHz) that emitted up to 2W (1 W at 1800 MHz). Pacemakers can be programmed with sensitivity from 0.1 mV to 5 mV, pulse width from 0.1 ms to 1.5 ms and pulse amplitude from 0.5 V to 5 V. The structural separation in three cardiac chambers (plus the one for the device) allowed a fast analysis procedure for dual- and tri-chamber implantable devices.

Entities:  

Mesh:

Year:  2003        PMID: 14572005     DOI: 10.1007/BF02345317

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  10 in total

1.  In-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators.

Authors:  J A Chiladakis; P Davlouros; G Agelopoulos; A S Manolis
Journal:  Eur Heart J       Date:  2001-08       Impact factor: 29.983

2.  Electromagnetic interference of analog cellular telephones with pacemakers.

Authors:  V Barbaro; P Bartolini; A Donato; C Militello
Journal:  Pacing Clin Electrophysiol       Date:  1996-10       Impact factor: 1.976

3.  Electromagnetic interference of pacemakers by mobile phones.

Authors:  W Irnich; L Batz; R Müller; R Tobisch
Journal:  Pacing Clin Electrophysiol       Date:  1996-10       Impact factor: 1.976

4.  Wireless phones and pacemaker interaction.

Authors:  D L Hayes
Journal:  Pacing Clin Electrophysiol       Date:  1996-10       Impact factor: 1.976

5.  In vitro testing of pacemakers for digital cellular phone electromagnetic interference.

Authors:  P S Ruggera; D M Witters; H I Bassen
Journal:  Biomed Instrum Technol       Date:  1997 Jul-Aug

6.  The influence of electromagnetic environment on the performance of artificial cardiac pacemakers.

Authors:  S Furman; B Parker; M Krauthamer; D J Escher
Journal:  Ann Thorac Surg       Date:  1968-07       Impact factor: 4.330

7.  Electromagnetic interference of digital and analog cellular telephones with implantable cardioverter defibrillators: in vitro and in vivo studies.

Authors:  V Barbaro; P Bartolini; F Bellocci; F Caruso; A Donato; D Gabrielli; C Militello; A S Montenero; P Zecchi
Journal:  Pacing Clin Electrophysiol       Date:  1999-04       Impact factor: 1.976

8.  Digital cellular telephone interaction with implantable cardioverter-defibrillators.

Authors:  J G Fetter; V Ivans; D G Benditt; J Collins
Journal:  J Am Coll Cardiol       Date:  1998-03-01       Impact factor: 24.094

9.  Cellular phone interference testing of implantable cardiac defibrillators in vitro.

Authors:  H I Bassen; H J Moore; P S Ruggera
Journal:  Pacing Clin Electrophysiol       Date:  1998-09       Impact factor: 1.976

10.  Do European GSM mobile cellular phones pose a potential risk to pacemaker patients?

Authors:  V Barbaro; P Bartolini; A Donato; C Militello; G Altamura; F Ammirati; M Santini
Journal:  Pacing Clin Electrophysiol       Date:  1995-06       Impact factor: 1.976

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.