The present study examines the potential electromagnetic interference effects induced by cellular telephones on ICDs. We developed ad hoc protocols to conduct both in vitro and in vivo trials on most of the implantable cardioverter defibrillators available on the international market. Trials were conducted with three cellular telephones: two GSM (Global System for Mobile Communication) and one TACS (Total Access Communication System). A human trunk simulator was used to carry out in vitro observations on six ICDs from five manufacturers. In vivo tests were conducted on 13 informed patients with eight different ICD models. During the trials in air, GSM telephones induced interference effects on 4 out of the 6 cardioverter defibrillators tested. Specifically, pulse inhibition, reprogramming, false ventricular fibrillation, and ventricular tachycardia detections occurred, which would have entailed inappropriate therapy delivery had this been activated. Effects were circumscribed to the area closely surrounding the connectors. When the ICD was immersed in saline solution, no effects were observed. Three cases of just ventricular triggering with the interfering signal were observed in vivo.

Entities:  

Mesh:

Year:  1999        PMID: 10234716     DOI: 10.1111/j.1540-8159.1999.tb00504.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

Review 1.  [Perioperative management of patients with implanted pacemakers or cardioverter/defibrillators. Recommendations of the Austrian Society for Anaesthesiology, Resuscitation and Intensive Care Medicine, the Austrian Society for Cardiology and the Austrian Society for Surgery].

Authors:  H Gombotz; M Anelli Monti; N Leitgeb; M Nürnberg; B Strohmer
Journal:  Anaesthesist       Date:  2009-05       Impact factor: 1.041

2.  Effects of mobile telephones on the function of implantable cardioverter defibrillators.

Authors:  Izzet Tandogan; Bulent Ozin; Huseyin Bozbas; Sibel Turhan; Ramazan Ozdemir; Ertan Yetkin; Ergun Topal
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-10       Impact factor: 1.468

3.  Electromagnetic interference in patients with implanted cardioverter-defibrillators and implantable loop recorders.

Authors:  Marcos de Sousa; Gunnar Klein; Thomas Korte; Michael Niehaus
Journal:  Indian Pacing Electrophysiol J       Date:  2002-07-01

4.  Safety of a combined strength and endurance training using neuromuscular electrical stimulation of thigh muscles in patients with heart failure and bipolar sensing cardiac pacemakers.

Authors:  Richard Crevenna; Winfried Mayr; Mohammad Keilani; Johannes Pleiner; Martin Nuhr; Michael Quittan; Richard Pacher; Veronika Fialka-Moser; Michael Wolzt
Journal:  Wien Klin Wochenschr       Date:  2003-10-31       Impact factor: 1.704

5.  A novel heart/trunk simulator for the study of electromagnetic interference with active implantable devices.

Authors:  A Angeloni; V Barbaro; P Bartolini; G Calcagnini; F Censi
Journal:  Med Biol Eng Comput       Date:  2003-09       Impact factor: 3.079

6.  Interference between cellular telephones and implantable rhythm devices: a review on recent papers.

Authors:  Johnson Francis; Michael Niehaus
Journal:  Indian Pacing Electrophysiol J       Date:  2006-10-01

7.  Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-III.

Authors:  Wolfgang Kainz; François Alesch; Dulciana Dias Chan
Journal:  Biomed Eng Online       Date:  2003-05-07       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.