The SCGM1 System: subcutaneous continuous glucose monitoring based on microdialysis technique.

Michael Schoemaker1, Elisabeth Andreis, Josef Röper, Reinhard Kotulla, Volker Lodwig, Karin Obermaier, Peter Stephan, Wilhelm Reuschling, Malte Rutschmann, Ralf Schwaninger, Uwe Wittmann, Helmut Rinne, Heinz Kontschieder, Werner Strohmeier.   

Abstract

The SCGM1 System is designed to allow continuous glucose monitoring in the subcutaneous interstitial fluid for up to 120 h. The system is based on the microdialysis technique and is composed of three components: (1) a disposable Cassette, which contains the microdialysis catheter (with the necessary tubes), an electrochemical flow-through sensor for glucose measurement, and the fluid reservoirs for both the microdialysis perfusate and a reagent solution containing glucose oxidase; (2) the Sensor Unit, which houses the Cassette and is worn by the patient using a belt pack; and (3) the Data Manager, with an integrated blood glucose meter for the calibration of the glucose signal. The Data Manager also has the option of displaying the continuous glucose signal. The Sensor Unit and Data Manager exchange glucose data and calibration data by radio transmission. In vitro precision was assessed by measurements of two standard glucose solutions (90 mg/dL, 3.4%; 360 mg/dL, 2.4%) over a time course of 4 days. The mean difference (+/- SD) between SCGM1 System devices (n = 11) and 15 glucose standard solutions with different concentrations was 1.4 +/- 3.5 mg/dL. The mean relative difference and the mean absolute relative difference ranged from - 0.6% to 3.7% and from 0.2% to 3.8%, respectively. The inherent physical lag time was 31 +/- 2 min (n = 10). The interference on the glucose signal of ascorbic acid, acetaminophen, and uric acid at the highest physiological concentrations was below 4%. The SCGM1 System showed a reliable and precise performance under in vitro conditions.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14511414     DOI: 10.1089/152091503322250613

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  12 in total

Review 1.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

2.  TheClinical Research Tool: a high-performance microdialysis-based system for reliably measuring interstitial fluid glucose concentration.

Authors:  Gregor Ocvirk; Martin Hajnsek; Ralph Gillen; Arnfried Guenther; Gernot Hochmuth; Ulrike Kamecke; Karl-Heinz Koelker; Peter Kraemer; Karin Obermaier; Cornelia Reinheimer; Nina Jendrike; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

Review 3.  Delays in minimally invasive continuous glucose monitoring devices: a review of current technology.

Authors:  D Barry Keenan; John J Mastrototaro; Gayane Voskanyan; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

4.  Continuous glucose profiles in healthy subjects under everyday life conditions and after different meals.

Authors:  Guido Freckmann; Sven Hagenlocher; Annette Baumstark; Nina Jendrike; Ralph C Gillen; Katja Rössner; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2007-09

5.  Feasibility of overnight closed-loop control based on hourly blood glucose measurements.

Authors:  Caroline Patte; Stefan Pleus; Paul Galley; Stefan Weinert; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2012-07-01

6.  Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas.

Authors:  Shinji Ichimori; Kenro Nishida; Seiya Shimoda; Taiji Sekigami; Yasuto Matsuo; Kenshi Ichinose; Motoaki Shichiri; Michiharu Sakakida; Eiichi Araki
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

7.  Use of microdialysis-based continuous glucose monitoring to drive real-time semi-closed-loop insulin infusion.

Authors:  Guido Freckmann; Nina Jendrike; Stefan Pleus; Harvey Buck; Steven Bousamra; Paul Galley; Ajay Thukral; Robin Wagner; Stefan Weinert; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2014-09-09

8.  Effect of Continuous Glucose Monitoring Accuracy on Clinicians' Retrospective Decision Making in Diabetes: A Pilot Study.

Authors:  Zeinab Mahmoudi; Mette Dencker Johansen; Hanne Holdflod Nørgaard; Steen Andersen; Ulrik Pedersen-Bjergaard; Lise Tarnow; Jens Sandahl Christiansen; Ole Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2015-06-08

9.  Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes.

Authors: 
Journal:  Pediatr Diabetes       Date:  2006-02       Impact factor: 4.866

10.  Clinical evaluation of subcutaneous lactate measurement in patients after major cardiac surgery.

Authors:  Martin Ellmerer; Martin Haluzik; Jan Blaha; Jaromir Kremen; Stepan Svacina; Andreas Plasnik; Dimas Ikeoka; Manfred Bodenlenz; Lukas Schaupp; Johannes Plank; Thomas R Pieber
Journal:  Int J Endocrinol       Date:  2009-05-26       Impact factor: 3.257

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.