Literature DB >> 8943635

Value of intraoperative image intensifier prints in trauma surgery.

R L Williams1, F S Haddad, A J Clarke.   

Abstract

We have studied the use of image intensification in a trauma theatre over a period of 6 months with particular reference to the acquisition of intraoperative image intensifier thermal prints instead of formal radiographs. The quality of the prints and the savings generated have been assessed. During the study period, 476 patients underwent orthopaedic trauma procedures. The image intensifier was used for intraoperative screening in 280 patients. In 278 of these a thermal print was obtained. This was used, instead of formal check radiographs, to plan further management in 210 patients (75%). In 68 patients, the printout was insufficient in its coverage of the operated area, and a check radiograph was also obtained. In no case did the clarity of the thermal image hinder accurate interpretation. We believe that thermal images are a useful substitute for formal postoperative radiographs in many trauma cases, and that, with notable exceptions, their use could decrease costs, reduce patient discomfort and radiation dose and spare overloaded radiology services.

Entities:  

Mesh:

Year:  1996        PMID: 8943635      PMCID: PMC2502856     

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  3 in total

1.  Ionising radiation: are orthopaedic surgeons at risk?

Authors:  G L Smith; T W Briggs; C B Lavy; H Nordeen
Journal:  Ann R Coll Surg Engl       Date:  1992-09       Impact factor: 1.891

2.  Ionising radiation and the orthopaedic surgeon.

Authors:  D E Hynes; T Conere; M B Mee; W F Cashman
Journal:  J Bone Joint Surg Br       Date:  1992-05

3.  Exposure of the orthopaedic surgeon to radiation.

Authors:  R Sanders; K J Koval; T DiPasquale; G Schmelling; S Stenzler; E Ross
Journal:  J Bone Joint Surg Am       Date:  1993-03       Impact factor: 5.284

  3 in total
  2 in total

1.  Closed reduction internal fixation rates and procedure times for metacarpal fractures treated in a minor surgery area before and after the introduction of a mini C-arm unit.

Authors:  R C Mahabir; C M DeCroff; L Thurgood; A R Harrop
Journal:  Can J Plast Surg       Date:  2008

2.  Effect of introduction of mini C-arm image intensifier in orthopaedic theatre.

Authors:  S P White
Journal:  Ann R Coll Surg Engl       Date:  2007-04       Impact factor: 1.891

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.