Literature DB >> 26891126

A radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging.

Jinil Park1,2, Taehoon Shin3, Soon Ho Yoon4,5, Jin Mo Goo4,5,6, Jang-Yeon Park1,2.   

Abstract

The purpose of this work was to develop a 3D radial-sampling strategy which maintains uniform k-space sample density after retrospective respiratory gating, and demonstrate its feasibility in free-breathing ultrashort-echo-time lung MRI. A multi-shot, interleaved 3D radial sampling function was designed by segmenting a single-shot trajectory of projection views such that each interleaf samples k-space in an incoherent fashion. An optimal segmentation factor for the interleaved acquisition was derived based on an approximate model of respiratory patterns such that radial interleaves are evenly accepted during the retrospective gating. The optimality of the proposed sampling scheme was tested by numerical simulations and phantom experiments using human respiratory waveforms. Retrospectively, respiratory-gated, free-breathing lung MRI with the proposed sampling strategy was performed in healthy subjects. The simulation yielded the most uniform k-space sample density with the optimal segmentation factor, as evidenced by the smallest standard deviation of the number of neighboring samples as well as minimal side-lobe energy in the point spread function. The optimality of the proposed scheme was also confirmed by minimal image artifacts in phantom images. Human lung images showed that the proposed sampling scheme significantly reduced streak and ring artifacts compared with the conventional retrospective respiratory gating while suppressing motion-related blurring compared with full sampling without respiratory gating. In conclusion, the proposed 3D radial-sampling scheme can effectively suppress the image artifacts due to non-uniform k-space sample density in retrospectively respiratory-gated lung MRI by uniformly distributing gated radial views across the k-space.
Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  3D radial UTE imaging; k-space sample uniformity; lung MRI; retrospective respiratory gating

Mesh:

Year:  2016        PMID: 26891126      PMCID: PMC4833643          DOI: 10.1002/nbm.3494

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  32 in total

1.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

2.  Evaluation of lung volumetry using dynamic three-dimensional magnetic resonance imaging.

Authors:  Christian Plathow; Max Schoebinger; Christian Fink; Sebastian Ley; Michael Puderbach; Monika Eichinger; Michael Bock; Hans-Peter Meinzer; Hans-Ulrich Kauczor
Journal:  Invest Radiol       Date:  2005-03       Impact factor: 6.016

3.  Lattice permutation for reducing motion artifacts in radial and spiral dynamic imaging.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

4.  Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction.

Authors:  C Stehning; P Börnert; K Nehrke; H Eggers; M Stuber
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

5.  Comparison of respiratory suppression methods and navigator locations for MR coronary angiography.

Authors:  M V McConnell; V C Khasgiwala; B J Savord; M H Chen; M L Chuang; R R Edelman; W J Manning
Journal:  AJR Am J Roentgenol       Date:  1997-05       Impact factor: 3.959

6.  Continuous radial data acquisition for dynamic MRI.

Authors:  V Rasche; R W de Boer; D Holz; R Proksa
Journal:  Magn Reson Med       Date:  1995-11       Impact factor: 4.668

7.  A strategy for sampling on a sphere applied to 3D selective RF pulse design.

Authors:  S T Wong; M S Roos
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

8.  Boron-11 imaging with a three-dimensional reconstruction method.

Authors:  G H Glover; J M Pauly; K M Bradshaw
Journal:  J Magn Reson Imaging       Date:  1992 Jan-Feb       Impact factor: 4.813

9.  Magnetic resonance fluoroscopy using spirals with variable sampling densities.

Authors:  D M Spielman; J M Pauly; C H Meyer
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

10.  MR imaging of the lungs: value of short TE spin-echo pulse sequences.

Authors:  J R Mayo; A MacKay; N L Müller
Journal:  AJR Am J Roentgenol       Date:  1992-11       Impact factor: 3.959

View more
  4 in total

1.  Gradient-echo-based 3D submillisecond echo time pulmonary MR imaging: a preliminary usability study on clinical and preclinical MR scanners.

Authors:  Soon Ho Yoon; Chanhee Lee; Jinil Park; Jin Mo Goo; Jang-Yeon Park
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

2.  Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI.

Authors:  Hyunyeol Lee; Xia Zhao; Hee Kwon Song; Felix W Wehrli
Journal:  IEEE Trans Med Imaging       Date:  2020-03-04       Impact factor: 10.048

3.  Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging.

Authors:  M Krämer; A G Motaal; K-H Herrmann; B Löffler; J R Reichenbach; G J Strijkers; V Hoerr
Journal:  J Cardiovasc Magn Reson       Date:  2017-03-31       Impact factor: 5.364

4.  Magnetisation transfer as a biomarker for chronic airway fibrosis in a mouse lung transplantation model.

Authors:  David Kenkel; Yoshito Yamada; Markus Weiger; Moritz C Wurnig; Wolfgang Jungraithmayr; Andreas Boss
Journal:  Eur Radiol Exp       Date:  2018-02-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.