Literature DB >> 1398820

Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants.

E A Patterson1, R B Johns.   

Abstract

Metal fatigue failure of the gold screw used to retain a fixed prosthesis to Brånemark osseointegrated fixtures/abutments has been analyzed theoretically. Mechanical engineering principles show the importance of appropriate preload being applied through the gold screw to the gold cylinder and abutment. The significance of the screw design and necessity of applying the correct torque to achieve a long fatigue life for the screw are also described. The consequence of misalignment of a gold cylinder to an abutment is discussed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1398820

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  12 in total

1.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

2.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

3.  Resistance of three implant-abutment interfaces to fatigue testing.

Authors:  Cleide Gisele Ribeiro; Maria Luiza Cabral Maia; Susanne S Scherrer; Antonio Carlos Cardoso; H W Anselm Wiskott
Journal:  J Appl Oral Sci       Date:  2011-07-01       Impact factor: 2.698

4.  Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.

Authors:  Ki-Joon Yoon; Young-Bum Park; Hyunmin Choi; Youngsung Cho; Jae-Hoon Lee; Keun-Woo Lee
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

5.  Stability of the prosthetic screws of three types of craniofacial prostheses retention systems.

Authors:  Antonio Gabriel Lanata-Flores; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; José Ricardo de Albergaria-Barbosa
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-12-27

Review 6.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

7.  Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study).

Authors:  Eman Mohammed Nasr Attiah; Attiah Ali AlGendy; Tamer Mohamed Nasr Mostafa
Journal:  Int J Implant Dent       Date:  2020-07-28

8.  Fractures of implant fixtures: a retroscccpective clinical study.

Authors:  Han-Chang Yu; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2020-04-25

Review 9.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

10.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

View more