Literature DB >> 1396768

Evaluation of a new commercial system for the identification of Enterobacteriaceae and non-fermentative bacteria.

H K Geiss1, M Geiss.   

Abstract

The performance of a new commercial semi-automatic system (Cobas Micro, Becton Dickinson) for identification of gram-negative fermentative and non-fermentative bacilli was evaluated using strains of clinical origin belonging to 48 different species. Two groups of strains were tested: 510 strains using a long incubation period (21 hours) and 158 strains using a short incubation period (5 hours). The correct identification rate without additional tests was 95.5% and 94.3% for the tests using a long and short incubation period respectively. The findings suggest that the system is highly accurate in the identification of most clinically important gram-negative rods, but shows some shortcomings in the identification of non-fermentative bacteria. The system is easy to use, and with some changes in the database and the inclusion of gram-positive and anaerobic bacteria would offer a valuable alternative to currently available automatic identification systems.

Mesh:

Year:  1992        PMID: 1396768     DOI: 10.1007/bf01961667

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  2 in total

1.  Description and evaluation of the semiautomated 4-hour ATB 32E method for identification of members of the family Enterobacteriaceae.

Authors:  J Freney; C Herve; M Desmonceaux; F Allard; J M Boeufgras; D Monget; J Fleurette
Journal:  J Clin Microbiol       Date:  1991-01       Impact factor: 5.948

2.  Comparison of AMS-Vitek, MicroScan, and Autobac Series II for the identification of gram-negative bacilli.

Authors:  A L Truant; E Starr; C A Nevel; M Tsolakis; E F Fiss
Journal:  Diagn Microbiol Infect Dis       Date:  1989 May-Jun       Impact factor: 2.803

  2 in total
  4 in total

1.  Parallel comparison of accuracy of API 20E, Vitek GNI, MicroScan Walk/Away Rapid ID, and Becton Dickinson Cobas Micro ID-E/NF for identification of members of the family Enterobacteriaceae and common gram-negative, non-glucose-fermenting bacilli.

Authors:  C M O'Hara; F C Tenover; J M Miller
Journal:  J Clin Microbiol       Date:  1993-12       Impact factor: 5.948

2.  Comparison of Vitek and Cobas Micro systems with a semiautomated conventional microsystem for identification and susceptibility testing of gram negative bacilli.

Authors:  A M Simoons-Smit; D M Maclaren
Journal:  J Clin Pathol       Date:  1994-01       Impact factor: 3.411

3.  Evaluation of a semi-automated 24-hour commercial system for identification of Enterobacteriaceae and other gram-negative bacteria.

Authors:  D Monnet; D Lafay; M Desmonceaux; J M Boeufgras; F Allard; J Freney
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-05       Impact factor: 3.267

4.  Identification of Hafnia alvei with the MicroScan WalkAway system.

Authors:  L A Rodríguez; J Vivas; C S Gallardo; F Acosta; L Barbeyto; F Real
Journal:  J Clin Microbiol       Date:  1999-12       Impact factor: 5.948