Literature DB >> 2676327

Comparison of AMS-Vitek, MicroScan, and Autobac Series II for the identification of gram-negative bacilli.

A L Truant1, E Starr, C A Nevel, M Tsolakis, E F Fiss.   

Abstract

Identification of Gram-negative bacilli by AMS-Vitek, MicroScan, and Autobac Series II was evaluated with 434 clinical isolates comprising glucose fermenters and glucose nonfermenters. The organisms were tested in each of the three systems (the AMS Vitek GNI card, the MicroScan Combo Plus Panel, and the Autobac 18 chamber cuvette). API 20E was used as the primary reference system. MicroScan and Vitek correctly identified 96.1% and 95.6% of the organisms, respectively. The Autobac Series II identified 82.3% of the organisms correctly. Results with MicroScan, Vitek, and Autobac were available in 24-48 hours, 4-18 hours, and 3-8 hours, respectively.

Entities:  

Mesh:

Year:  1989        PMID: 2676327     DOI: 10.1016/0732-8893(89)90017-5

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  5 in total

1.  Evaluation of a new commercial system for the identification of Enterobacteriaceae and non-fermentative bacteria.

Authors:  H K Geiss; M Geiss
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1992-07       Impact factor: 3.267

Review 2.  Automated systems for identification of microorganisms.

Authors:  C E Stager; J R Davis
Journal:  Clin Microbiol Rev       Date:  1992-07       Impact factor: 26.132

3.  Parallel comparison of accuracy of API 20E, Vitek GNI, MicroScan Walk/Away Rapid ID, and Becton Dickinson Cobas Micro ID-E/NF for identification of members of the family Enterobacteriaceae and common gram-negative, non-glucose-fermenting bacilli.

Authors:  C M O'Hara; F C Tenover; J M Miller
Journal:  J Clin Microbiol       Date:  1993-12       Impact factor: 5.948

4.  Comparison of Vitek and Cobas Micro systems with a semiautomated conventional microsystem for identification and susceptibility testing of gram negative bacilli.

Authors:  A M Simoons-Smit; D M Maclaren
Journal:  J Clin Pathol       Date:  1994-01       Impact factor: 3.411

5.  Infective Endocarditis: Identification of Catalase-Negative, Gram-Positive Cocci from Blood Cultures by Partial 16S rRNA Gene Analysis and by Vitek 2 Examination.

Authors:  Rawaa Jalil Abdul-Redha; Michael Kemp; Jette M Bangsborg; Magnus Arpi; Jens Jørgen Christensen
Journal:  Open Microbiol J       Date:  2010-12-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.