Abstract

In vivo 1H conventional NMR image contrast generation usually relies on the macroscopic T1 and T2 relaxation parameters of the tissues of interest. Recently cross-relaxation related image contrast has been reported by Wolff and Balaban in animal models. Due primarily to the broad lineshape of the intended saturation spin pool and the use of off-resonance irradiation, high specific absorption rate and an auxiliary RF amplifier have been necessary to produce these images. The relatively long spin-lattice relaxation property of this spin pool, however, suggests the use of pulse methods to achieve saturation. In this paper, we show that short-T2 spin pools can be selectively saturated with short intense RF pulses. Cross-relaxation time constants can be measured using the technique of saturation recovery. In vivo magnetization-transfer-weighted images can be produced using pulses on commercial whole-body imagers without additional hardware.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1325023     DOI: 10.1002/mrm.1910260205

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

Review 1.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

2.  A new approach for on-resonance magnetization transfer parameter optimization.

Authors:  D Grenier; S Deval; A Briguet
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

3.  MTR variations in normal adult brain structures using balanced steady-state free precession.

Authors:  Meritxell Garcia; Monika Gloor; Oliver Bieri; Stephan G Wetzel; Ernst-Wilhelm Radue; Klaus Scheffler
Journal:  Neuroradiology       Date:  2010-05-18       Impact factor: 2.804

Review 4.  Alternatives to gadolinium-based metal chelates for magnetic resonance imaging.

Authors:  Subha Viswanathan; Zoltan Kovacs; Kayla N Green; S James Ratnakar; A Dean Sherry
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

5.  Optimization of on-resonant magnetization transfer contrast in coronary vein MRI.

Authors:  Christian T Stoeck; Peng Hu; Dana C Peters; Kraig V Kissinger; Beth Goddu; Lois Goepfert; Long Ngo; Warren J Manning; Sebastian Kozerke; Reza Nezafat
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

Review 6.  Magnetization transfer imaging of multiple sclerosis.

Authors:  G B Pike
Journal:  Ital J Neurol Sci       Date:  1997-12

7.  Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

Authors:  X P Zhu; P B Chilvers; C E Hutchinson; G A Morris; J M Hawnaur; J E Adams; C J Taylor
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

8.  Magnetization transfer with echo planar imaging.

Authors:  J P Ranjeva; J M Franconi; C Manelfe; I Berry
Journal:  MAGMA       Date:  1997-12       Impact factor: 2.310

9.  Magnetization transfer contrast MRI of musculoskeletal neoplasms.

Authors:  K C Li; K L Hopkins; S G Moore; N N Loh; G Bergman; G B Pike; G H Glover
Journal:  Skeletal Radiol       Date:  1995-01       Impact factor: 2.199

10.  Rapid measurement of brain macromolecular proton fraction with transient saturation transfer MRI.

Authors:  Peter van Gelderen; Xu Jiang; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2016-06-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.