Literature DB >> 10050939

A new approach for on-resonance magnetization transfer parameter optimization.

D Grenier1, S Deval, A Briguet.   

Abstract

On-resonance radio frequency pulse sequences for magnetization transfer are optimized using a frequency domain approach. The method presented here was developed using binomial pulses and it is demonstrated that a simple analysis leads to accurate sequence parameters that can be used directly for magnetic resonance imaging. With thus optimized parameters it is possible to produce an efficient saturation of protons having short transverse relaxation time while protons with long transverse relaxation time are kept nearly unaffected by the radio frequency. The method is particularly well suited to the design of new magnetization transfer sequences and to the estimation of the limits of the accuracy of a T2 selection. Additionally in vitro tests have been performed on beef tendon oriented with a zero fiber to field angle.

Mesh:

Year:  1998        PMID: 10050939     DOI: 10.1007/bf02591330

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  10 in total

1.  Pulsed saturation transfer contrast.

Authors:  B S Hu; S M Conolly; G A Wright; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-08       Impact factor: 4.668

2.  Selective excitation in Fourier transform nuclear magnetic resonance. 1978.

Authors:  Gareth A Morris; Ray Freeman
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

3.  Optimization of T2-selective binomial pulses for magnetization transfer.

Authors:  M Pachot-Clouard; L Darrasse
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

4.  Orientation of tendons in the magnetic field and its effect on T2 relaxation times.

Authors:  G D Fullerton; I L Cameron; V A Ord
Journal:  Radiology       Date:  1985-05       Impact factor: 11.105

5.  Magnetization transfer by simple sequences of rectangular pulses.

Authors:  J Forster; F Schick; M Pfeffer; O Lutz
Journal:  MAGMA       Date:  1995-07       Impact factor: 2.310

6.  A model for magnetization transfer in tissues.

Authors:  C Morrison; R M Henkelman
Journal:  Magn Reson Med       Date:  1995-04       Impact factor: 4.668

7.  Magnetization transfer in cross-linked bovine serum albumin solutions at 200 MHz: a model for tissue.

Authors:  S H Koenig; R D Brown; R Ugolini
Journal:  Magn Reson Med       Date:  1993-03       Impact factor: 4.668

8.  Quantitative interpretation of magnetization transfer.

Authors:  R M Henkelman; X Huang; Q S Xiang; G J Stanisz; S D Swanson; M J Bronskill
Journal:  Magn Reson Med       Date:  1993-06       Impact factor: 4.668

9.  Pulsed magnetization transfer spin-echo MR imaging.

Authors:  G B Pike; G H Glover; B S Hu; D R Enzmann
Journal:  J Magn Reson Imaging       Date:  1993 May-Jun       Impact factor: 4.813

10.  Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo.

Authors:  S D Wolff; R S Balaban
Journal:  Magn Reson Med       Date:  1989-04       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.