In vitro performance test system for pulse oximeters.

K J Reynolds1, J T Moyle, L B Gale, M K Sykes, C E Hahn.   

Abstract

An in vitro system was developed capable of testing the accuracy and reproducibility of pulse oximeter readings. The pulse oximeter probe receives signals through a pulsating blood cuvette. The development of the design of the cuvette is described. Using the final design (or 'model finger'), a comparison is made between readings from a Datex Satlite pulse oximeter (SpO2) and saturation values obtained by use of a multi-wavelength bench oximeter (SaO2). Linear regression analysis of the data gives SpO2 = 0.88 SaO2 + 11.2 (r = 0.979, p < 0.001).

Entities:  

Mesh:

Year:  1992        PMID: 1297018     DOI: 10.1007/bf02446795

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  Comparison of four pulse oximeters: effects of venous occlusion and cold-induced peripheral vasoconstriction.

Authors:  J A Langton; D Lassey; C D Hanning
Journal:  Br J Anaesth       Date:  1990-08       Impact factor: 9.166

2.  Response of 10 pulse oximeters to an in vitro test system.

Authors:  K J Reynolds; J T Moyle; M K Sykes; C E Hahn
Journal:  Br J Anaesth       Date:  1992-04       Impact factor: 9.166

3.  New contributions to the optics of intensely light-scattering materials.

Authors:  P KUBELKA
Journal:  J Opt Soc Am       Date:  1948-05

4.  Computer-controlled pulsatile pump system for physiological flow simulation.

Authors:  Y F Law; R S Cobbold; K W Johnston; P A Bascom
Journal:  Med Biol Eng Comput       Date:  1987-09       Impact factor: 2.602

5.  Absorption and multiple scattering by biological suspensions.

Authors:  V Twersky
Journal:  J Opt Soc Am       Date:  1970-08

6.  Development of pump system for experimental model simulation of blood flow in peripheral artery.

Authors:  T Kiyose; A Kusaba; M Kamori; K Inokuchi; Y Takamatsu
Journal:  Fukuoka Igaku Zasshi       Date:  1977-02

7.  Limitations of pulse oximetry.

Authors:  A Huch; R Huch; V König; M R Neuman; D Parker; J Yount; D Lübbers
Journal:  Lancet       Date:  1988-02-13       Impact factor: 79.321

8.  Errors in 14 pulse oximeters during profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh; S O Koh
Journal:  J Clin Monit       Date:  1989-04

9.  Noninvasive pulse oximetry in children with cyanotic congenital heart disease.

Authors:  R A Boxer; I Gottesfeld; S Singh; M A LaCorte; V A Parnell; P Walker
Journal:  Crit Care Med       Date:  1987-11       Impact factor: 7.598

10.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

View more
  6 in total

1.  Non-invasive continuous estimation of blood flow changes in human patellar bone.

Authors:  Jan Näslund; Jonas Pettersson; Thomas Lundeberg; Dag Linnarsson; Lars-Göran Lindberg
Journal:  Med Biol Eng Comput       Date:  2006-06-03       Impact factor: 2.602

2.  Reflectance pulse oximetry at the forehead improves by pressure on the probe.

Authors:  A C Dassel; R Graaff; M Sikkema; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1995-07

3.  Development system for pulse oximetry.

Authors:  T Leuthner
Journal:  Med Biol Eng Comput       Date:  1994-09       Impact factor: 2.602

4.  A prototype device for standardized calibration of pulse oximeters II.

Authors:  Ch Hornberger; Ph Knoop; H Matz; F Dörries; E Konecny; H Gehring; J Otten; R Bonk; H Frankenberger; P Wouters; J Gil-Rodriguez; L Ponz; J Avgerinos; A Karoutis; A Ikiades; S Weininger
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

5.  Hypoxia-enhanced adhesion of red blood cells in microscale flow.

Authors:  Myeongseop Kim; Yunus Alapan; Anima Adhikari; Jane A Little; Umut A Gurkan
Journal:  Microcirculation       Date:  2017-07       Impact factor: 2.628

6.  A prototype device for standardized calibration of pulse oximeters.

Authors:  C Hornberger; P Knoop; W Nahm; H Matz; E Konecny; H Gehring; R Bonk; H Frankenberger; G Meyfroidt; P Wouters; J Gil-Rodriguez; L Ponz; K Benekos; J Valais; J Avgerinos; A Karoutis; A Ikiades; S Weininger
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.