Literature DB >> 12964659

Image quality in digital radiographic systems.

Solange Maria de Almeida1, Ana Emília Figueiredo de Oliveira, Rívea Inês Ferreira, Frab Norberto Bóscolo.   

Abstract

The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA. 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p < 0.01) in image quality with the four systems. Based on the results, it was possible to conclude that: 1) all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2) higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device); 3) the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12964659     DOI: 10.1590/s0103-64402003000200012

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  9 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

2.  The effect of delayed scanning of storage phosphor plates on occlusal caries detection.

Authors:  E Sogur; B G Baksi; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

3.  The effect of anatomical noise on perception of low contrast in intra-oral radiographs: an in vitro study.

Authors:  Lars Olsson; Mats Nilsson; Björn Svenson; Kristina Hellén-Halme
Journal:  Dentomaxillofac Radiol       Date:  2016-02-19       Impact factor: 2.419

4.  Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study.

Authors:  Kristina Hellén-Halme
Journal:  Clin Oral Investig       Date:  2010-02-09       Impact factor: 3.573

5.  Revisiting dynamic range and image enhancement ability of contemporary digital radiographic systems.

Authors:  Luiz Eduardo Marinho-Vieira; Luciano Augusto Cano Martins; Deborah Queiroz Freitas; Francisco Haiter-Neto; Matheus L Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2021-12-14       Impact factor: 3.525

6.  Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study.

Authors:  Mohammad Mahdi Yaghooti Khorasani; Hamed Ebrahimnejad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20

7.  Diagnosis of Approximal Caries after Delayed Scanning of Photostimulable Phosphor Plates.

Authors:  Zahra Ghoncheh; Yasaman Kheirandish; Hanieh Kaviani; Mohammad Javad Kharazi Fard; Kurosh Sadeghi
Journal:  J Dent (Shiraz)       Date:  2017-09

8.  Conventional versus digital radiography in detecting root canal type in maxillary premolars: an in vitro study.

Authors:  Mahkameh Moshfeghi; Soodabeh Sadat Sajadi; Sepideh Sajadi; Majid Shahbazian
Journal:  J Dent (Tehran)       Date:  2013-01-31

9.  The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.

Authors:  Bart Vandenberghe; Reinhilde Jacobs
Journal:  J Oral Maxillofac Res       Date:  2010-04-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.