Literature DB >> 12955523

Physiological responses during cycling with noncircular "Harmonic" and circular chainrings.

Sébastien Ratel1, Pascale Duché, Christophe A Hautier, Craig A Williams, Mario Bedu.   

Abstract

The aim of the present study was to compare physiological data obtained during cycling using a noncircular "Harmonic" chainring versus a standard circular chainring over a range of speeds and slopes in endurance-trained cyclists. Thirteen male subnational cyclists (16-45 years) performed two maximal graded exercises on their own bicycle: one with a circular chainring, the other with a Harmonic chainring with the same gearwheel (52 teeth). The two chainrings were randomly assigned to avoid learning effects. The tests were carried out on a simulator. Speeds and/or slopes were increased every 2 min 30 s until exhaustion of the subject. Ventilation, oxygen uptake, carbon dioxide output, respiratory exchange ratio, and heart rate were continuously measured during the tests. Blood lactate concentration was measured during the last 30 s of each level. No significant difference was observed in any of the submaximal parameters measured during the tests ( P>0.05). Similarly, maximal values were not statistically different ( P>0.05). In conclusion, although the design of the Harmonic chainring was based on optimization analysis, comparison of the physiological response in this study did not translate into an advantage of the Harmonic over circular chainring during submaximal and maximal pedaling in trained cyclists.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12955523     DOI: 10.1007/s00421-003-0937-9

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  13 in total

1.  Muscle contributions to specific biomechanical functions do not change in forward versus backward pedaling.

Authors:  R R Neptune; S A Kautz; F E Zajac
Journal:  J Biomech       Date:  2000-02       Impact factor: 2.712

2.  Adaptation of muscle coordination to altered task mechanics during steady-state cycling.

Authors:  R R Neptune; W Herzog
Journal:  J Biomech       Date:  2000-02       Impact factor: 2.712

Review 3.  Biomechanical determinants of pedaling energetics: internal and external work are not independent.

Authors:  Steven A Kautz; Richard R Neptune
Journal:  Exerc Sport Sci Rev       Date:  2002-10       Impact factor: 6.230

4.  EMG profiles of lower extremity muscles during cycling at constant workload and cadence.

Authors:  M M Ryan; R J Gregor
Journal:  J Electromyogr Kinesiol       Date:  1992       Impact factor: 2.368

5.  Efficiency of trained cyclists using circular and noncircular chainrings.

Authors:  L K Cullen; K Andrew; K R Lair; M J Widger; B F Timson
Journal:  Int J Sports Med       Date:  1992-04       Impact factor: 3.118

6.  An angular velocity profile in cycling derived from mechanical energy analysis.

Authors:  M L Hull; S Kautz; A Beard
Journal:  J Biomech       Date:  1991       Impact factor: 2.712

7.  Bicycle pedalling forces as a function of pedalling rate and power output.

Authors:  R P Patterson; M I Moreno
Journal:  Med Sci Sports Exerc       Date:  1990-08       Impact factor: 5.411

8.  The effects of circular and elliptical chainwheels on steady-rate cycle ergometer work efficiency.

Authors:  S C Henderson; R W Ellis; G Klimovitch; G A Brooks
Journal:  Med Sci Sports       Date:  1977

9.  Plasma lactate and plasma volume recovery in adults and children following high-intensity exercises.

Authors:  S Berthoin; H Allender; G Baquet; G Dupont; R Matran; P Pelayo; H Robin
Journal:  Acta Paediatr       Date:  2003       Impact factor: 2.299

10.  Physiological response to cycling with both circular and noncircular chainrings.

Authors:  M L Hull; M Williams; K Williams; S Kautz
Journal:  Med Sci Sports Exerc       Date:  1992-10       Impact factor: 5.411

View more
  8 in total

1.  Cycling performance and mechanical variables using a new prototype chainring.

Authors:  Lucien Belen; Mickaël Habrard; Jean Paul Micallef; Stéphane Perrey; Daniel Le Gallais
Journal:  Eur J Appl Physiol       Date:  2007-09-04       Impact factor: 3.078

2.  The rotor pedaling system improves anaerobic but not aerobic cycling performance in professional cyclists.

Authors:  Jose A Rodríguez-Marroyo; Juan García-López; Karim Chamari; Alfredo Córdova; Olivier Hue; Jose G Villa
Journal:  Eur J Appl Physiol       Date:  2009-01-31       Impact factor: 3.078

Review 3.  The measurement of maximal (anaerobic) power output on a cycle ergometer: a critical review.

Authors:  Tarak Driss; Henry Vandewalle
Journal:  Biomed Res Int       Date:  2013-08-29       Impact factor: 3.411

4.  Effect of the rotor crank system on cycling performance.

Authors:  Simon A Jobson; James Hopker; Andrew Galbraith; Damian A Coleman; Alan M Nevill
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

5.  Does a non-circular chainring improve performance in the bicycle motocross cycling start sprint?

Authors:  Manuel Mateo-March; Eneko Fernández-Peña; Cristina Blasco-Lafarga; Jaime Morente-Sánchez; Mikel Zabala
Journal:  J Sports Sci Med       Date:  2014-01-20       Impact factor: 2.988

6.  Physiological Responses during Cycling With Oval Chainrings (Q-Ring) and Circular Chainrings.

Authors:  Alfredo Cordova; Iban Latasa; Jesus Seco; Gerardo Villa; Javier Rodriguez-Falces
Journal:  J Sports Sci Med       Date:  2014-05-01       Impact factor: 2.988

7.  Effects of a Non-Circular Chainring on Sprint Performance During a Cycle Ergometer Test.

Authors:  Frédérique Hintzy; Frédéric Grappe; Alain Belli
Journal:  J Sports Sci Med       Date:  2016-05-23       Impact factor: 2.988

8.  Validity of a Newly-Designed Rectilinear Stepping Ergometer Submaximal Exercise Test to Assess Cardiorespiratory Fitness.

Authors:  Rubin Zhang; Likui Zhan; Shaoming Sun; Wei Peng; Yining Sun
Journal:  J Sports Sci Med       Date:  2017-08-08       Impact factor: 2.988

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.