Literature DB >> 1601563

Efficiency of trained cyclists using circular and noncircular chainrings.

L K Cullen1, K Andrew, K R Lair, M J Widger, B F Timson.   

Abstract

The purpose of this study was to determine oxygen consumption (VO2), heart rate (HR) response, and rating of perceived exertion (RPE) of trained cyclists using noncircular and circular chainrings over a range of gears and pedal cadences. The subjects included 7 male cyclists (6 USCF licensed riders, 1 national qualifying triathlete). Each subject rode his own bicycle mounted on a wind-trainer at gears of 5.92 and 7.33 meters with noncircular and circular chainrings at pedal cadences of 50, 70, and 90 rpm. VO2, HR, RPE, and respiratory exchange ratio (RER) measurements were made during each of the 12 rides. Mean percent VO2max for each condition ranged from 28.7 +/- 2.1% with the 5.92 meter gear at 50 rpm to 83.4 +/- 4.3% using the 7.33 meter gear at 90 rpm. The results indicate no significant difference in any of the parameters measured between the two chainrings for any of the experimental conditions. The data indicate that the noncircular chainrings used in this study were not more efficient than the standard circular chainring for trained cyclists.

Entities:  

Mesh:

Year:  1992        PMID: 1601563     DOI: 10.1055/s-2007-1021264

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  9 in total

1.  Physiological responses during cycling with noncircular "Harmonic" and circular chainrings.

Authors:  Sébastien Ratel; Pascale Duché; Christophe A Hautier; Craig A Williams; Mario Bedu
Journal:  Eur J Appl Physiol       Date:  2003-09-04       Impact factor: 3.078

2.  Cycling performance and mechanical variables using a new prototype chainring.

Authors:  Lucien Belen; Mickaël Habrard; Jean Paul Micallef; Stéphane Perrey; Daniel Le Gallais
Journal:  Eur J Appl Physiol       Date:  2007-09-04       Impact factor: 3.078

Review 3.  Efficiency in cycling: a review.

Authors:  Gertjan Ettema; Håvard Wuttudal Lorås
Journal:  Eur J Appl Physiol       Date:  2009-02-20       Impact factor: 3.078

4.  The rotor pedaling system improves anaerobic but not aerobic cycling performance in professional cyclists.

Authors:  Jose A Rodríguez-Marroyo; Juan García-López; Karim Chamari; Alfredo Córdova; Olivier Hue; Jose G Villa
Journal:  Eur J Appl Physiol       Date:  2009-01-31       Impact factor: 3.078

Review 5.  The measurement of maximal (anaerobic) power output on a cycle ergometer: a critical review.

Authors:  Tarak Driss; Henry Vandewalle
Journal:  Biomed Res Int       Date:  2013-08-29       Impact factor: 3.411

6.  Effect of the rotor crank system on cycling performance.

Authors:  Simon A Jobson; James Hopker; Andrew Galbraith; Damian A Coleman; Alan M Nevill
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

7.  Physiological Responses during Cycling With Oval Chainrings (Q-Ring) and Circular Chainrings.

Authors:  Alfredo Cordova; Iban Latasa; Jesus Seco; Gerardo Villa; Javier Rodriguez-Falces
Journal:  J Sports Sci Med       Date:  2014-05-01       Impact factor: 2.988

8.  Effects of a Non-Circular Chainring on Sprint Performance During a Cycle Ergometer Test.

Authors:  Frédérique Hintzy; Frédéric Grappe; Alain Belli
Journal:  J Sports Sci Med       Date:  2016-05-23       Impact factor: 2.988

Review 9.  Applied physiology of triathlon.

Authors:  M L O'Toole; P S Douglas
Journal:  Sports Med       Date:  1995-04       Impact factor: 11.136

  9 in total