Literature DB >> 28912653

Validity of a Newly-Designed Rectilinear Stepping Ergometer Submaximal Exercise Test to Assess Cardiorespiratory Fitness.

Rubin Zhang1,2, Likui Zhan3, Shaoming Sun3, Wei Peng1,2, Yining Sun3.   

Abstract

The maximum oxygen uptake (V̇O2 max), determined from graded maximal or submaximal exercise tests, is used to classify the cardiorespiratory fitness level of individuals. The purpose of this study was to examine the validity and reliability of the YMCA submaximal exercise test protocol performed on a newly-designed rectilinear stepping ergometer (RSE) that used up and down reciprocating vertical motion in place of conventional circular motion and giving precise measurement of workload, to determine V̇O2 max in young healthy male adults. Thirty-two young healthy male adults (32 males; age range: 20-35 years; height: 1.75 ± 0.05 m; weight: 67.5 ± 8.6 kg) firstly participated in a maximal-effort graded exercise test using a cycle ergometer (CE) to directly obtain measured V̇O2 max. Subjects then completed the progressive multistage test on the RSE beginning at 50W and including additional stages of 70, 90, 110, 130, and 150W, and the RSE YMCA submaximal test consisting of a workload increase every 3 minutes until the termination criterion was reached. A metabolic equation was derived from the RSE multistage exercise test to predict oxygen consumption (V̇O2) from power output (W) during the submaximal exercise test (V̇O2 (mL·min-1 )=12.4 ×W(watts)+3.5 mL·kg-1·min-1×M+160mL·min-1, R2= 0.91, standard error of the estimate (SEE) = 134.8mL·min-1). A high correlation was observed between the RSE YMCA estimated V̇O2 max and the CE measured V̇O2 max (r=0.87). The mean difference between estimated and measured V̇O2 max was 2.5 mL·kg-1·min-1, with an SEE of 3.55 mL·kg-1·min-1. The data suggest that the RSE YMCA submaximal exercise test is valid for predicting V̇O2 max in young healthy male adults. The findings show that the rectilinear stepping exercise is an effective submaximal exercise for predicting V̇O2 max. The newly-designed RSE may be potentially further developed as an alternative ergometer for assessing cardiorespiratory fitness and the promotion of personalized health interventions for health care professionals.

Entities:  

Keywords:  Maximum oxygen uptake; constant power output; metabolic equation; rectilinear reciprocating motion

Year:  2017        PMID: 28912653      PMCID: PMC5592287     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  21 in total

1.  Electromyographic analysis of a human powered stepper cycle during seated and standing riding.

Authors:  M S Miller; J P Peach; T S Keller
Journal:  J Electromyogr Kinesiol       Date:  2001-12       Impact factor: 2.368

2.  Prediction of maximal VO2 from a submaximal StairMaster test in young women.

Authors:  Jane L P Roy; Joe F Smith; Phillip A Bishop; Christopher Hallinan; Minqi Wang; Gary R Hunter
Journal:  J Strength Cond Res       Date:  2004-02       Impact factor: 3.775

3.  Accurate prediction of VO2max in cycle ergometry.

Authors:  T W Storer; J A Davis; V J Caiozzo
Journal:  Med Sci Sports Exerc       Date:  1990-10       Impact factor: 5.411

4.  Validation of a new cycle ergometer.

Authors:  M F Glaner; R A S Silva
Journal:  Int J Sports Med       Date:  2010-12-16       Impact factor: 3.118

5.  Cross-validation of the YMCA submaximal cycle ergometer test to predict VO2max.

Authors:  Matthew D Beekley; William F Brechue; Diego V deHoyos; Linda Garzarella; Galila Werber-Zion; Michael L Pollock
Journal:  Res Q Exerc Sport       Date:  2004-09       Impact factor: 2.500

6.  Bicycle pedalling forces as a function of pedalling rate and power output.

Authors:  R P Patterson; M I Moreno
Journal:  Med Sci Sports Exerc       Date:  1990-08       Impact factor: 5.411

7.  Applying fuzzy logic to control cycling movement induced by functional electrical stimulation.

Authors:  J J Chen; N Y Yu; D G Huang; B T Ann; G C Chang
Journal:  IEEE Trans Rehabil Eng       Date:  1997-06

8.  Recumbent stepper submaximal exercise test to predict peak oxygen uptake.

Authors:  Sandra A Billinger; Ellie VAN Swearingen; Megan McClain; Angela A Lentz; Mathew B Good
Journal:  Med Sci Sports Exerc       Date:  2012-08       Impact factor: 5.411

9.  Exercise training in patients with chronic heart failure improves endothelial function predominantly in the trained extremities.

Authors:  Nobuhiko Kobayashi; Yoshio Tsuruya; Takamasa Iwasawa; Nahoko Ikeda; Shigemasa Hashimoto; Takanori Yasu; Hiroto Ueba; Norifumi Kubo; Mikihisa Fujii; Masanobu Kawakami; Muneyasu Saito
Journal:  Circ J       Date:  2003-06       Impact factor: 2.993

10.  Pedaling rate is an important determinant of human oxygen uptake during exercise on the cycle ergometer.

Authors:  Federico Formenti; Alberto E Minetti; Fabio Borrani
Journal:  Physiol Rep       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.