Literature DB >> 12953909

Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation.

Elbakri Idris A1, Jeffrey A Fessler.   

Abstract

This paper describes a statistical image reconstruction method for x-ray CT that is based on a physical model that accounts for the polyenergetic x-ray source spectrum and the measurement nonlinearities caused by energy-dependent attenuation. Unlike our earlier work, the proposed algorithm does not require pre-segmentation of the object into the various tissue classes (e.g., bone and soft tissue) and allows mixed pixels. The attenuation coefficient of each voxel is modelled as the product of its unknown density and a weighted sum of energy-dependent mass attenuation coefficients. We formulate a penalized-likelihood function for this polyenergetic model and develop an iterative algorithm for estimating the unknown density of each voxel. Applying this method to simulated x-ray CT measurements of objects containing both bone and soft tissue yields images with significantly reduced beam hardening artefacts relative to conventional beam hardening correction methods. We also apply the method to real data acquired from a phantom containing various concentrations of potassium phosphate solution. The algorithm reconstructs an image with accurate density values for the different concentrations, demonstrating its potential for quantitative CT applications.

Entities:  

Mesh:

Year:  2003        PMID: 12953909     DOI: 10.1088/0031-9155/48/15/314

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  34 in total

1.  Radiation dose reduction in temporal bone CT with iterative reconstruction technique.

Authors:  Y T Niu; D Mehta; Z R Zhang; Y X Zhang; Y F Liu; T L Kang; J F Xian; Z C Wang
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-09       Impact factor: 3.825

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  Achieving accurate radiochromic optical-CT imaging when using a polychromatic light source.

Authors:  A Thomas; M Pierquet; M Oldham
Journal:  J Phys Conf Ser       Date:  2010

4.  Adaptive correction of the pseudo-enhancement of CT attenuation for fecal-tagging CT colonography.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Med Image Anal       Date:  2008-01-26       Impact factor: 8.545

5.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

6.  Nonlinear regression-based method for pseudoenhancement correction in CT colonography.

Authors:  Baigalmaa Tsagaan; Janne Näppi; Hiroyuki Yoshida
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

7.  Statistical image reconstruction from correlated data with applications to PET.

Authors:  Adam Alessio; Ken Sauer; Paul Kinahan
Journal:  Phys Med Biol       Date:  2007-10-01       Impact factor: 3.609

8.  Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements.

Authors:  Thomas Blumensath; Richard Boardman
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

9.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

10.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.