Literature DB >> 12934226

Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty.

David Hendel1, Avraham Garti, Moshe Weisbort.   

Abstract

Between 1993 and 1998, 332 I-BII (Insall Burstein II) prostheses were implanted in our department. We studied 5 cases of tibial polyethylene spine fractures. The fractures occurred 3 to 5 years following the surgery. All cases with fractures had mild medial laxity that was noted on follow-up of 2 to 3 years following arthroplasty. One also developed mild hyperextension. All the patients had a revision surgery. In 2 cases, the polyethylene was changed to a thicker one, together with medial reinforcement. Three cases were revised to a rotating hinge prosthesis.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12934226     DOI: 10.1016/s0883-5403(03)00192-x

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Implant design influences tibial post wear damage in posterior-stabilized knees.

Authors:  Mark M Dolan; Natalie H Kelly; Joseph T Nguyen; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

2.  Tibial post wear in posterior-stabilized knee replacements is design-dependent.

Authors:  Bridgette D Furman; Joseph Lipman; Mordechai Kligman; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2008-08-14       Impact factor: 4.176

3.  Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report.

Authors:  Fabio D'Angelo; Daniele Marcolli; Paolo Bulgheroni; Luigi Murena; Terenzio Congiu; Paolo Cherubino
Journal:  J Med Case Rep       Date:  2010-02-23

Review 4.  How to treat a tibial post fracture in total knee arthroplasty? A systematic review.

Authors:  Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2010-10-21       Impact factor: 4.176

Review 5.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25

6.  Fracture of the insert cone of a polyethylene liner in a failed posterior-stabilized, rotating-platform total knee arthroplasty.

Authors:  Marc R Angerame; Jason M Jennings; Douglas A Dennis
Journal:  Arthroplast Today       Date:  2017-11-07

7.  Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F.

Authors:  Jun-Young Kim; Sang-Ho Cheon; Hee-Soo Kyung
Journal:  Knee Surg Relat Res       Date:  2012-11-29

8.  Fracture of the Anterior Locking Flange of a Total Knee Arthroplasty Polyethylene Liner Presenting with Pain following Knee Replacement.

Authors:  Richard Jeavons; Daniel Dowen; Paul Rushton; Daniel Ryan; Peter Gill
Journal:  J Orthop Case Rep       Date:  2014 Apr-Jun

9.  Nontraumatic Tibial Polyethylene Insert Cone Fracture in Rotating-Platform Total Knee Arthroplasty.

Authors:  Cillian J Keogh; David Keohane; James A Harty; David Mulcahy
Journal:  Arthroplast Today       Date:  2021-04-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.