Literature DB >> 12918576

Acute in vivo testing of a respiratory assist catheter: implants in calves versus sheep.

Heide J Eash1, Brian J Frankowski, Kenneth Litwak, William R Wagner, Brack G Hattler, William J Federspiel.   

Abstract

A respiratory catheter that is inserted through a peripheral vein and placed within the vena cava is being developed for CO2 removal in patients with acute exacerbations of chronic obstructive pulmonary disease (COPD). The catheter uses a rapidly pulsating balloon to enhance gas exchange. In this study, the CO2 removal performance of our catheter was assessed in acute sheep implants and compared with calf implants, primarily because sheep have cardiac outputs (CO) that are more comparable with human CO and lower than calves. Respiratory catheters (25 mL balloon, 0.17 m2) were inserted acutely in sheep (n = 2) and calves (n = 6) through the jugular vein and placed within the vena cava in two positions: spanning the right atrium (RA) and within the inferior vena cava (IVC). The postinsertion CO in the sheep ranged from 4.1 to 7.2 L/min compared with 6.2 to 15.5 L/min for the calves. The maximum CO2 removal rates (vCO2) were 297 ml/min/m2 (calf) and 282 ml/min/m2 (sheep) in the RA position and 240 ml/min/m2 (calf) and 248 ml/min/m2 (sheep) in the IVC position. The respective removal rates between animal models were not statistically different (p values > 0 .05 for all data sets). The dependence of the vCO2 on balloon pulsation was also not statistically different between the animal models.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918576      PMCID: PMC2002495          DOI: 10.1097/01.mat.0000074991.94234.b6

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  26 in total

1.  2000 Report of the AVMA Panel on Euthanasia.

Authors: 
Journal:  J Am Vet Med Assoc       Date:  2001-03-01       Impact factor: 1.936

2.  HeartMate II left ventricular assist system: from concept to first clinical use.

Authors:  B P Griffith; R L Kormos; H S Borovetz; K Litwak; J F Antaki; V L Poirier; K C Butler
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

3.  Acute in vivo testing of an intravascular respiratory support catheter.

Authors:  J F Golob; W J Federspiel; T L Merrill; B J Frankowski; K Litwak; H Russian; B G Hattler
Journal:  ASAIO J       Date:  2001 Sep-Oct       Impact factor: 2.872

Review 4.  Acute respiratory distress syndrome: physiology and new management strategies.

Authors:  A B Weinacker; L T Vaszar
Journal:  Annu Rev Med       Date:  2001       Impact factor: 13.739

5.  A mathematical model of gas exchange in an intravenous membrane oxygenator.

Authors:  T J Hewitt; B G Hattler; W J Federspiel
Journal:  Ann Biomed Eng       Date:  1998 Jan-Feb       Impact factor: 3.934

6.  A respiratory gas exchange catheter: in vitro and in vivo tests in large animals.

Authors:  Brack G Hattler; Laura W Lund; Joseph Golob; Heide Russian; Michael F Lann; Thomas L Merrill; Brian Frankowski; William J Federspiel
Journal:  J Thorac Cardiovasc Surg       Date:  2002-09       Impact factor: 5.209

7.  Use of an intravascular oxygenator/carbon dioxide removal device in an ovine smoke inhalation injury model.

Authors:  C S Cox; J B Zwischenberger; L D Traber; D L Traber; D N Herndon
Journal:  ASAIO Trans       Date:  1991 Jul-Sep

8.  Work of breathing in patients with chronic obstructive pulmonary disease in acute respiratory failure.

Authors:  B Fleury; D Murciano; C Talamo; M Aubier; R Pariente; J Milic-Emili
Journal:  Am Rev Respir Dis       Date:  1985-06

9.  Validation of a model for flow-dependent carbon dioxide exchange in artificial lungs.

Authors:  M S Hout; B G Hattler; W J Federspiel
Journal:  Artif Organs       Date:  2000-02       Impact factor: 3.094

Review 10.  Treatment of acute exacerbations in chronic obstructive pulmonary disease.

Authors:  R L Rosen; R C Bone
Journal:  Med Clin North Am       Date:  1990-05       Impact factor: 5.456

View more
  5 in total

1.  Evaluation of local gas exchange in a pulsating respiratory support catheter.

Authors:  Heide J Eash; Brian J Frankowski; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2005 Mar-Apr       Impact factor: 2.872

2.  Blood biocompatibility assessment of an intravenous gas exchange device.

Authors:  Trevor A Snyder; Heide J Eash; Kenneth N Litwak; Brian J Frankowski; Brack G Hattler; William J Federspiel; William R Wagner
Journal:  Artif Organs       Date:  2006-09       Impact factor: 3.094

3.  Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter.

Authors:  Heide J Eash; Kevin M Mihelc; Brian J Frankowski; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2007 May-Jun       Impact factor: 2.872

4.  Low-Dose Heparin Anticoagulation During Extracorporeal Life Support for Acute Respiratory Distress Syndrome in Conscious Sheep.

Authors:  Nicolas J Prat; Andrew D Meyer; Thomas Langer; Robbie K Montgomery; Bijaya K Parida; Andriy I Batchinsky; Andrew P Cap
Journal:  Shock       Date:  2015-12       Impact factor: 3.454

5.  Suitable CO2 Solubility Models for Determination of the CO2 Removal Performance of Oxygenators.

Authors:  Benjamin Lukitsch; Paul Ecker; Martin Elenkov; Christoph Janeczek; Christian Jordan; Claus G Krenn; Roman Ullrich; Margit Gfoehler; Michael Harasek
Journal:  Bioengineering (Basel)       Date:  2021-03-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.