Literature DB >> 10718764

Validation of a model for flow-dependent carbon dioxide exchange in artificial lungs.

M S Hout1, B G Hattler, W J Federspiel.   

Abstract

The exchange rate of CO2 in artificial lungs depends on the sweep gas flow rate. Control of the amount of CO2 removed by an artificial lung requires quantitative knowledge of the flow dependence. A simple model of the dependence of CO2 exchange on sweep gas flow rate in artificial lungs has been previously presented (1). For a given partial pressure of CO2 in the blood phase, sweep gas flow rate, and CO2 exchange rate, the model indicates how close the CO2 exchange rate is to the maximum level attainable by the artificial lung. The focus of this study was to validate the model experimentally by testing 2 commercial artificial lungs in an in vitro test loop. The CO2 exchange rate for each artificial lung was measured over a range of sweep gas flow rates. Linear regression was used to fit the data to the model and estimate the maximum possible CO2 exchange rate and the average water-side PCO2 (PCO2w). The difference between the measured and regressed values of PCO2w was used as an indicator of the ability of the model to quantitatively predict the dependence of CO2 exchange on gas flow rate. This difference was less than 5% for each experiment, indicating that the model can be used to guide control of CO2 exchange rates in artificial lungs.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10718764     DOI: 10.1046/j.1525-1594.2000.06465.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  6 in total

1.  Quantification of Carbon Dioxide Removal at Low Sweep Gas and Blood Flows.

Authors:  Juan de Villiers Hugo; Ajay S Sharma; Usaama Ahmed; Patrick W Weerwind
Journal:  J Extra Corpor Technol       Date:  2017-12

Review 2.  Extracorporeal carbon dioxide removal (ECCO2R) in respiratory deficiency and current investigations on its improvement: a review.

Authors:  Hany Hazfiza Manap; Ahmad Khairi Abdul Wahab
Journal:  J Artif Organs       Date:  2016-05-18       Impact factor: 1.731

3.  Apnea test for brain death determination in a patient on extracorporeal membrane oxygenation.

Authors:  Pierre Smilevitch; Laurent Lonjaret; Olivier Fourcade; Thomas Geeraerts
Journal:  Neurocrit Care       Date:  2013-10       Impact factor: 3.210

4.  Acute in vivo testing of a respiratory assist catheter: implants in calves versus sheep.

Authors:  Heide J Eash; Brian J Frankowski; Kenneth Litwak; William R Wagner; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2003 Jul-Aug       Impact factor: 2.872

Review 5.  Brain death: a clinical overview.

Authors:  William Spears; Asim Mian; David Greer
Journal:  J Intensive Care       Date:  2022-03-16

6.  Water as a Blood Model for Determination of CO2 Removal Performance of Membrane Oxygenators.

Authors:  Benjamin Lukitsch; Raffael Koller; Paul Ecker; Martin Elenkov; Christoph Janeczek; Markus Pekovits; Bahram Haddadi; Christian Jordan; Margit Gfoehler; Michael Harasek
Journal:  Membranes (Basel)       Date:  2021-05-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.