Performance evaluation of a "dual-side read" dedicated mammography computed radiography system.

Kenneth A Fetterly1, Beth A Schueler.   

Abstract

The image quality of a dedicated mammography computed radiography (CR) system was characterized. A unique feature of this system is that it collects image signals from both sides of the storage phosphor. Measurements of the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were made. This work included improvements in our measurement methods to specifically account for the detrimental effects of system glare on the MTF and to accurately characterize the low-frequency NPS components. Image quality measurements were performed using a 25 kVp beam filtered with 2 mm Al and an exposure range of 1 to 100 mR (87 to 870 microGy). The DQE was found to decrease with increasing exposure due to an increased contribution of storage phosphor structure noise. The DQE of this system was compared to similar measurements made using a standard CR system. The dual-side read system demonstrated superior DQE compared to the standard system. The decrease in DQE with increasing exposure was more severe for the standard system than the dual-side read system. This finding suggests that the CR system noise was reduced for the dual-side read system compared to the standard system.

Entities:  

Mesh:

Year:  2003        PMID: 12906203     DOI: 10.1118/1.1584045

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Diagnostic quality of 50 and 100 μm computed radiography compared with screen-film mammography in operative breast specimens.

Authors:  C M Pagliari; T Hoang; M Reddy; L S Wilkinson; J D Poloniecki; R M Given-Wilson
Journal:  Br J Radiol       Date:  2011-11-17       Impact factor: 3.039

2.  Emerging Breast Imaging Technologies on the Horizon.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Semin Ultrasound CT MR       Date:  2017-09-13       Impact factor: 1.875

3.  ROC study of four LCD displays under typical medical center lighting conditions.

Authors:  Steve Langer; Ken Fetterly; Jay Mandrekar; Scott Harmsen; Brian Bartholmai; Charles Patton; Alan Bishop; Colin McCannel
Journal:  J Digit Imaging       Date:  2006-03       Impact factor: 4.056

4.  Effect of readout direction in the edge profile on the modulation transfer function of computed radiographic systems by use of the edge method.

Authors:  Nobukazu Tanaka; Junji Morishita; Norisato Tsuda; Masafumi Ohki
Journal:  Radiol Phys Technol       Date:  2013-06-04

5.  Digital magnification mammography with matched incident exposure: physical imaging properties and detectability of simulated microcalcifications.

Authors:  Nobukazu Tanaka; Kentaro Naka; Hiroko Fukushima; Junji Morishita; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2011-03-18

6.  Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Authors:  Nobukazu Tanaka; Yuki Yano; Hidetake Yabuuchi; Tsutomu Akasaka; Masayuki Sasaki; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2012-11-10

7.  Dose reduction in general radiography for adult patients by use of a dual-side-reading photostimulable phosphor plate in a computed radiography system.

Authors:  Norisato Tsuda; Nobukazu Tanaka; Tsutomu Akasaka; Hidetake Yabuuchi; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2014-05-21

8.  Modeling the performance characteristics of computed radiography (CR) systems.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

Review 9.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

Review 10.  [Digital radiography of the chest in pediatric patients].

Authors:  S Puig
Journal:  Radiologe       Date:  2003-12       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.