Literature DB >> 12893696

A contribution to the establishment of diagnostic reference levels in CT.

K Hatziioannou1, E Papanastassiou, M Delichas, P Bousbouras.   

Abstract

CT has become the major source of population exposure to diagnostic X-rays. CT dose index (CTDI) and dose-length product (DLP) have been proposed as the appropriate dose quantities for the establishment of diagnostic reference levels for optimizing patient exposure. Dose measurements on 27 CT scanners in Northern Greece involving six routine CT examinations have been performed in order to compare their performance with the currently proposed European reference dose values and to produce a preliminary set of data for the establishment of local diagnostic reference levels. All measurements were performed using a pencil shaped ionization chamber introduced into polymethyl methacrylate cylindrical head and body phantoms. The results revealed significant discrepancies in dose values among the CT scanners, which can be mainly attributed to variations in the examination protocols and the different kinds of scanners. Significant overdosing compared with the European reference levels has not been observed, with the exception of the routine head examination, where 47% of the scanners exceeded the corresponding CTDI(w) value. CT scans in the trunk region result in the higher effective doses, which can reach estimated maximal values of the order of 15 mSv.

Entities:  

Mesh:

Year:  2003        PMID: 12893696     DOI: 10.1259/bjr/60897046

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

1.  Radiation safety concerns and diagnostic reference levels for computed tomography scanners in Tamil Nadu.

Authors:  Roshan S Livingstone; Paul M Dinakaran
Journal:  J Med Phys       Date:  2011-01

2.  Dose management in CT facility.

Authors:  V Tsapaki; M Rehani
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

3.  Visual grading characteristics and ordinal regression analysis during optimisation of CT head examinations.

Authors:  Francis Zarb; Mark F McEntee; Louise Rainford
Journal:  Insights Imaging       Date:  2014-12-16

4.  Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India.

Authors:  A Saravanakumar; K Vaideki; K N Govindarajan; S Jayakumar
Journal:  J Med Phys       Date:  2014-01

5.  Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran.

Authors:  A Janbabanezhad Toori; A Shabestani-Monfared; M R Deevband; R Abdi; M Nabahati
Journal:  J Biomed Phys Eng       Date:  2015-12-01

6.  How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?

Authors:  Saravanabavaan Suntharalingam; Franz Ferdinand Stecker; Nika Guberina; Adrian Ringelstein; Thomas Schlosser; Jens Matthias Theysohn; Michael Forsting; Kai Nassenstein
Journal:  PLoS One       Date:  2016-04-06       Impact factor: 3.240

7.  Machine Learning Techniques Applied to Dose Prediction in Computed Tomography Tests.

Authors:  Antonio-Javier Garcia-Sanchez; Enrique Garcia Angosto; Jose Luis Llor; Alfredo Serna Berna; David Ramos
Journal:  Sensors (Basel)       Date:  2019-11-22       Impact factor: 3.576

  7 in total