Literature DB >> 12886472

Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating.

T Trabold1, M Buchgeister, A Küttner, M Heuschmid, A F Kopp, S Schröder, C D Claussen.   

Abstract

PURPOSE: We sought to evaluate the radiation exposure of cardiac CT scans with 16-row multidetector computed tomography (MDCT). Additionally the possibility of dose reduction by using a ECG-controlled tube current modulation technique was evaluated. METHODS AND MATERIAL: An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Effective dose was calculated according to ICRP 60. Exposure was performed on a 16-row MDCT scanner with standard protocols for CT coronary calcium scoring (120 kV, 133 mAs, 12 x 1.5 mm) and CT coronary angiography (120 kV, 400 mAs, 12 x 0.75 mm). Exposure was repeated at a simulated heart rate of 60 bpm with ECG-pulsed tube current modulation.
RESULTS: Effective dose was 2.9 mSv (male) and 3.6 mSv (female) for the calcium scoring protocol. CT coronary angiography resulted in an effective dose of 8.1 mSv (male) and 10.9 mSv (female). Using ECG-pulsed tube current modulation radiation exposure can significant reduced: by 46 % (1.6 mSv) in calcium scoring and by 47 % (4.3 mSv) in CT coronary angiography.
CONCLUSION: MDCT of the heart shows a significant radiation exposure, which can significantly be reduced by ECG-pulsed tube current modulation. Radiation exposure of cardiac MDCT is comparable to CT-examinations of chest or abdomen, but seem to be slightly higher compared to conventional coronary angiography.

Entities:  

Mesh:

Year:  2003        PMID: 12886472     DOI: 10.1055/s-2003-40926

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  41 in total

Review 1.  Assessment of pulmonary hypertension by CT and MR imaging.

Authors:  Sebastian Ley; Karl-Friedrich Kreitner; Christian Fink; Claus P Heussel; Mathias M Borst; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2004-01-23       Impact factor: 5.315

2.  Multi-slice spiral computed tomography: useful for non-invasive coronary angiography?

Authors:  Stephen Schroeder; Jeroen J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2004-02       Impact factor: 2.357

3.  Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality.

Authors:  Jean-François Paul
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-18       Impact factor: 2.357

4.  Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: a phantom study.

Authors:  Lukas Lehmkuhl; Dieter Gosch; H D Nagel; Patrick Stumpp; Thomas Kahn; Matthias Gutberlet
Journal:  Eur Radiol       Date:  2010-04-09       Impact factor: 5.315

5.  Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients.

Authors:  Damien Delhaye; Martine Remy-Jardin; Randa Salem; Antoine Teisseire; Chadi Khalil; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-08-29       Impact factor: 5.315

6.  Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

Authors:  Martin Heuschmid; Julia K Rothfuss; Stephen Schroeder; Michael Fenchel; Norbert Stauder; Christof Burgstahler; Andreas Franow; Ronald S Kuzo; Axel Kuettner; Stephan Miller; Claus D Claussen; Andreas F Kopp
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

7.  Noninvasive visualization of the coronary arteries with multi-slice computed tomography; influence of heart rate on diagnostic accuracy.

Authors:  Maureen M Henneman; Jeroen J Bax; Joanne D Schuijf; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2005-12-10       Impact factor: 2.357

Review 8.  Non-invasive multislice CT coronary imaging.

Authors:  Nico R Mollet; Filippo Cademartiri; Pim J de Feyter
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

Review 9.  Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography.

Authors:  Thomas C Gerber; Ronald S Kuzo; Richard L Morin
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

10.  Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program.

Authors:  C Hohl; G Mühlenbruch; J E Wildberger; C Leidecker; C Süss; T Schmidt; R W Günther; A H Mahnken
Journal:  Eur Radiol       Date:  2006-02-03       Impact factor: 5.315

View more