Literature DB >> 12873942

The bispectral index declines during neuromuscular block in fully awake persons.

M Messner1, U Beese, J Romstöck, M Dinkel, K Tschaikowsky.   

Abstract

UNLABELLED: Bispectral index (BIS) is an electroencephalographic variable promoted for measuring depth of anesthesia. Electromyographic activity influences surface electroencephalography and the calculation of BIS. In this study, we sought to determine the effect of spontaneous electromyographic activity on BIS. BIS was monitored in three volunteers by using an Aspect A-1000 monitor. The experiment was repeated in one volunteer. Electromyographic activity was recorded. Alcuronium and succinylcholine were administered. No other drugs were used. In parallel with spontaneous electromyographic activity of the facial muscles, BIS decreased in response to muscle relaxation to a minimum value of 33 and, in the repeated measurement, to a minimum value of 9 when total neuromuscular block was achieved. In two volunteers, no total block was achieved. BIS decreased to a minimal value of 64 and 57, respectively. In turn, recovery of BIS coincided with the reappearance of spontaneous electromyographic activity. During the entire experiment, the volunteers had full consciousness. BIS, assessed by software Version 3.31, correlates with spontaneous electromyographic activity of the facial muscles. BIS failed to detect awareness in completely paralyzed subjects. Thus, in paralyzed patients, BIS monitoring may not reliably indicate a decline in sedation and imminent awareness. IMPLICATIONS: The bispectral index (BIS) is an electroencephalographic variable intended for measuring depth of anesthesia. Electromyographic activity influences the calculation of BIS. We found that the administration of a muscle relaxant to unanesthetized volunteers decreases the bispectral index value. Thus, awareness in totally paralyzed patients cannot be excluded.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12873942     DOI: 10.1213/01.ane.0000072741.78244.c0

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  45 in total

1.  Comparison of SNAP™ II and BIS Vista indices during normothermic cardiopulmonary bypass under isoflurane anesthesia.

Authors:  Kinjal M Patel; Saadia S Sherwani; Paul C Fitzgerald; Robert J McCarthy
Journal:  J Clin Monit Comput       Date:  2011-11-11       Impact factor: 2.502

2.  Comparison of the EEG-based SNAP index and the Bispectral (BIS) index during sevoflurane-nitrous oxide anaesthesia.

Authors:  P Ruiz-Gimeno; M Soro; A Pérez-Solaz; M Carrau; F J Belda; J L Jover; G Aguilar
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

3.  BIS monitor findings during self-hypnosis.

Authors:  Christopher M Burkle; Christopher J Jankowski; Laurence C Torsher; Edwin H Rho; Amy C Degnim
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

Review 4.  [Measurement of the depth of anaesthesia].

Authors:  G N Schmidt; J Müller; P Bischoff
Journal:  Anaesthesist       Date:  2008-01       Impact factor: 1.041

5.  Response entropy is more reactive than bispectral index during laparoscopic gastric banding.

Authors:  James Feld; William E Hoffman
Journal:  J Clin Monit Comput       Date:  2006-07-04       Impact factor: 2.502

6.  Age-dependency of sevoflurane-induced electroencephalogram dynamics in children.

Authors:  O Akeju; K J Pavone; J A Thum; P G Firth; M B Westover; M Puglia; E S Shank; E N Brown; P L Purdon
Journal:  Br J Anaesth       Date:  2015-07       Impact factor: 9.166

7.  Effect of rocuronium on the bispectral index under anesthesia and tracheal intubation.

Authors:  Hui Yue; Jinyu Han; Ling Liu; Kaiyuan Wang; Jincheng Li
Journal:  Exp Ther Med       Date:  2016-10-20       Impact factor: 2.447

8.  Anaesthesia monitoring by recurrence quantification analysis of EEG data.

Authors:  Klaus Becker; Gerhard Schneider; Matthias Eder; Andreas Ranft; Eberhard F Kochs; Walter Zieglgänsberger; Hans-Ulrich Dodt
Journal:  PLoS One       Date:  2010-01-26       Impact factor: 3.240

9.  Peak and averaged bicoherence for different EEG patterns during general anaesthesia.

Authors:  Stacey Pritchett; Eugene Zilberg; Zheng Ming Xu; Paul Myles; Ian Brown; David Burton
Journal:  Biomed Eng Online       Date:  2010-11-20       Impact factor: 2.819

10.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.