Literature DB >> 12869007

Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis.

Kivanç Akça1, Murat Cavit Cehreli, Haldun Iplikçioğlu.   

Abstract

The purpose of this study was to evaluate the mechanical characteristics of the implant-abutment connection of a reduced-diameter ITI dental implant. A finite element model of a slashed circle 3.3 mm x 10 mm ITI solid-screw implant and a 6 degrees solid abutment 4 mm in height was constructed, and the implant-abutment complex was embedded vertically in the center of a slashed circle 1.5 cm x 1.5 cm acrylic cylinder. Static vertical and oblique loads of 300 N were applied in separate load cases. The contact area was defined between the implant-abutment connection and nonlinear finite element stress analysis was performed. The magnitude and distribution of Von Mises stresses and displacement characteristics were evaluated. In vertical loading, Von Mises stresses concentrated around the implant-abutment connection at the stem of the screw and around the implant collar. Oblique loading resulted in a 2-fold increase in stresses at the implant collar, which was close to the yield strength of titanium. Displacement values under both loading conditions were negligible. We conclude that, in a reduced-diameter ITI dental implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. The neck of this implant is a potential zone for fracture when subjected to high bending forces. The reduced-diameter ITI dental implant might benefit from reinforcement of this region.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12869007     DOI: 10.1034/j.1600-0501.2003.00828.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  16 in total

1.  3D finite element analysis to detect stress distribution: spiral family implants.

Authors:  Matteo Danza; Ilaria Zollino; Luigi Paracchini; Guidi Riccardo; Stefano Fanali; Francesco Carinci
Journal:  J Maxillofac Oral Surg       Date:  2010-04-24

2.  Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis.

Authors:  Kivanc Akca; Murat Cavit Cehreli
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

3.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

Review 4.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

Review 5.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

6.  Nonlinear finite element analysis of three implant- abutment interface designs.

Authors:  Chun-Bo Tang; Si-Yu Liul; Guo-Xing Zhou; Jin-Hua Yu; Guang-Dong Zhang; Yi-Dong Bao; Qiu-Ju Wang
Journal:  Int J Oral Sci       Date:  2012-06       Impact factor: 6.344

7.  Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-06-18

8.  Three dimensional finite element analysis to detect stress distribution in spiral implants and surrounding bone.

Authors:  Matteo Danza; Annalisa Palmieri; Francesca Farinella; Giorgio Brunelli; Francesco Carinci; Ambra Girardi; Giuseppe Spinelli
Journal:  Dent Res J (Isfahan)       Date:  2009

9.  Developing a new dental implant design and comparing its biomechanical features with four designs.

Authors:  Mansour Rismanchian; Reza Birang; Mahdi Shahmoradi; Hassan Talebi; Reza Jabar Zare
Journal:  Dent Res J (Isfahan)       Date:  2010

10.  Use of Narrow-Diameter Implants in Completely Edentulous Patients as a Prosthetic Option: A Systematic Review of the Literature.

Authors:  S Storelli; A Caputo; G Palandrani; M Peditto; M Del Fabbro; E Romeo; G Oteri
Journal:  Biomed Res Int       Date:  2021-06-22       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.