Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty.

Stephen M Belkoff1, Sean Molloy.   

Abstract

STUDY
DESIGN: Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies.
OBJECTIVE: To measure internal vertebral body temperature during polymerization of cements used for vertebroplasty. SUMMARY OF BACKGROUND DATA: Previous ex vivo studies have shown that temperature increases during cement polymerization were unlikely to cause thermal necrosis.
METHODS: Twenty-four osteoporotic vertebral bodies were instrumented with thermocouples and injected with one of two cement volumes (6 or 10 mL) of one of two cements (Simplex P or modified Simplex P, Stryker-Howmedica-Osteonics, Kalamazoo, MI). Vertebral bodies were placed in a bath (37 C) and temperatures were measured for 15 minutes from the time the cement was initially mixed.
RESULTS: In the vertebral bodies, peak temperatures at the anterior cortex ranged from 44 C to 113 C, those in the center ranged from 49 C to 112 C, and those at the spinal canal ranged from 39 C to 57 C. Dwell times at temperatures above 50 C at the anterior cortex ranged from 0 to 5.5 minutes, those in the center ranged from 0 to 8 minutes, and those at the spinal canal ranged from 0 to 2.5 minutes.
CONCLUSION: Internal temperature elevation measured during cement polymerization was substantially higher than previously reported and may be sufficiently high to pose a risk of thermal necrosis.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12865844

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  60 in total

1.  [Cement distribution in vertebroplasty pedicle screws with different designs].

Authors:  K Kafchitsas; F Geiger; M Rauschmann; S Schmidt
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

2.  [Filler materials for augmentation of osteoporotic vertebral fractures].

Authors:  M Arabmotlagh; M Rauschmann
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

3.  Osteoporotic vertebral compression fractures augmentation by injectable partly resorbable ceramic bone substitute (Cerament™|SPINE SUPPORT): a prospective nonrandomized study.

Authors:  Salvatore Masala; Giovanni Nano; Stefano Marcia; Mario Muto; Francesco Paolo Maria Fucci; Giovanni Simonetti
Journal:  Neuroradiology       Date:  2011-08-11       Impact factor: 2.804

4.  Intraspinal leakage of bone cement after vertebroplasty: a report of 3 cases.

Authors:  M M H Teng; H Cheng; D M-T Ho; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

5.  Thoraco-lumbar traumatic vertebral fractures augmentation by osteo-conductive and osteo-inductive bone substitute containing strontium-hydroxyapatite: our experience.

Authors:  Salvatore Masala; Amedeo Taglieri; Antonio Chiaravalloti; Eros Calabria; Marco Morini; Riccardo Iundusi; Umberto Tarantino; Giovanni Simonetti
Journal:  Neuroradiology       Date:  2014-03-21       Impact factor: 2.804

6.  [Kyphoplasty and vertebroplasty. Indications, techniques, complications and results].

Authors:  B Schmidt-Rohlfing; H Reilmann; R Pfeifer; P Kobbe; H C Pape
Journal:  Unfallchirurg       Date:  2011-05       Impact factor: 1.000

7.  Evaluation of the in vitro cell-material interactions and in vivo osteo-integration of a spinal acrylic bone cement.

Authors:  Sophie Verrier; Lisa Hughes; Antoine Alves; Marianna Peroglio; Mauro Alini; Andreas Boger
Journal:  Eur Spine J       Date:  2011-08-03       Impact factor: 3.134

8.  Percutaneous cement augmentation for the treatment of depression fractures of the tibial plateau.

Authors:  D S Evangelopoulos; S Heitkemper; S Eggli; U Haupt; A K Exadaktylos; L M Benneker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-12-15       Impact factor: 4.342

9.  Percutaneous osteoplasty for the management of a femoral head metastasis: a case report.

Authors:  Wei-Guo Wang; Chun-Gen Wu; Yi-Feng Gu; Ming-Hua Li
Journal:  Korean J Radiol       Date:  2009 Nov-Dec       Impact factor: 3.500

10.  Mechanical properties of blood-mixed polymethylmetacrylate in percutaneous vertebroplasty.

Authors:  Dong Ki Ahn; Song Lee; Dea Jung Choi; Soon Yeol Park; Dae Gon Woo; Chi Hoon Kim; Han Sung Kim
Journal:  Asian Spine J       Date:  2009-12-31