Literature DB >> 12852541

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63.

Chester Reft1, Rodica Alecu, Indra J Das, Bruce J Gerbi, Paul Keall, Eugene Lief, Ben J Mijnheer, Nikos Papanikolaou, Claudio Sibata, Jake Van Dyk.   

Abstract

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for radiation oncology patients with high-Z hip prostheses.

Entities:  

Mesh:

Year:  2003        PMID: 12852541     DOI: 10.1118/1.1565113

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  61 in total

1.  Dose attenuation effect of hip prostheses in a 9-MV photon beam: commercial treatment planning system versus Monte Carlo calculations.

Authors:  Asghar Mesbahi; Farshad Seyed Nejad
Journal:  Radiat Med       Date:  2007-12-25

2.  Investigation of various energy deposition kernel refinements for the convolution∕superposition method.

Authors:  Jessie Y Huang; David Eklund; Nathan L Childress; Rebecca M Howell; Dragan Mirkovic; David S Followill; Stephen F Kry
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

3.  Effects and consequences of Digisonic SP cochlear implant on radiotherapy planning.

Authors:  Nicolas Guevara; Ibrahim Atean; David Benoit; Yoann Pointreau; Gaëlle Angellier; Serge Marcie; Sonia Saaï; Dan Gnansia; Juliette Thariat
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-03-07       Impact factor: 2.503

4.  An evaluation of three commercially available metal artifact reduction methods for CT imaging.

Authors:  Jessie Y Huang; James R Kerns; Jessica L Nute; Xinming Liu; Peter A Balter; Francesco C Stingo; David S Followill; Dragan Mirkovic; Rebecca M Howell; Stephen F Kry
Journal:  Phys Med Biol       Date:  2015-01-14       Impact factor: 3.609

5.  Benchmark measurements and simulations of dose perturbations due to metallic spheres in proton beams.

Authors:  Wayne D Newhauser; Laura Rechner; Dragan Mirkovic; Pablo Yepes; Nicholas C Koch; Uwe Titt; Jonas D Fontenot; Rui Zhang
Journal:  Radiat Meas       Date:  2013-11-01       Impact factor: 1.898

6.  Approaches to reducing photon dose calculation errors near metal implants.

Authors:  Jessie Y Huang; David S Followill; Rebecca M Howell; Xinming Liu; Dragan Mirkovic; Francesco C Stingo; Stephen F Kry
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

7.  Volumetric modulated arc therapy in prostate cancer patients with metallic hip prostheses in a UK centre.

Authors:  Wee Loon Ng; John Brunt; Simon Temple; Mohammed Saipillai; Anoop Haridass; Helen Wong; Zafar Malik; Chinnamani Eswar
Journal:  Rep Pract Oncol Radiother       Date:  2015-04-14

8.  PET/MR imaging of the pelvis in the presence of endoprostheses: reducing image artifacts and increasing accuracy through inpainting.

Authors:  Claes Nøhr Ladefoged; Flemming Littrup Andersen; Sune Høgild Keller; Johan Löfgren; Adam Espe Hansen; Søren Holm; Liselotte Højgaard; Thomas Beyer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-01-08       Impact factor: 9.236

9.  Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry.

Authors:  G G Alves; A Kinoshita; H F de Oliveira; F S Guimarães; L L Amaral; O Baffa
Journal:  Braz J Med Biol Res       Date:  2015-05-26       Impact factor: 2.590

10.  Dose distribution near thin titanium plate for skull fixation irradiated by a 4-MV photon beam.

Authors:  Tomohiro Shimozato; Keisuke Yasui; Ryota Kawanami; Kousaku Habara; Yuichi Aoyama; Katsuyoshi Tabushi; Yasunori Obata
Journal:  J Med Phys       Date:  2010-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.