Literature DB >> 12815698

Fat-suppressed steady-state free precession imaging using phase detection.

Brian A Hargreaves1, Shreyas S Vasanawala, Krishna S Nayak, Bob S Hu, Dwight G Nishimura.   

Abstract

Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetition time (TR). Appropriate selection of the TR results in a 180 degrees phase difference between lipid and water signals. This phase difference can be used for fat-water separation in SSFP without any increase in scan time. The technique is shown to produce excellent non-contrast-enhanced, flow-independent angiograms of the peripheral vasculature. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12815698     DOI: 10.1002/mrm.10488

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  38 in total

Review 1.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

2.  High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold: parallel imaging with extended cardiac data acquisition.

Authors:  Jaeseok Park; Andrew C Larson; Qiang Zhang; Orlando Simonetti; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

3.  S5FP: spectrally selective suppression with steady state free precession.

Authors:  J A Derbyshire; D A Herzka; E R McVeigh
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

4.  Prospective intraindividual comparison between respiratory-triggered balanced steady-state free precession and breath-hold gradient-echo and time-of-flight magnetic resonance imaging for assessment of portal and hepatic veins.

Authors:  Jürgen K Willmann; Kerstin Göpfert; Amelie M Lutz; Daniel Nanz; Lucas McCormack; Henrik Petrowsky; Burkhardt Seifert; Patrice Hervo; Borut Marincek; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

5.  Abdominal fat-water separation with SSFP at 3 Tesla.

Authors:  Janaka P Wansapura
Journal:  Pediatr Radiol       Date:  2006-11-07

6.  Fast four-dimensional coronary MR angiography with k-t GRAPPA.

Authors:  Peng Lai; Feng Huang; Andrew C Larson; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

7.  A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels.

Authors:  Kjell-Inge Gjesdal; Tryggve Storaas; Jonn-Terje Geitung
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

8.  Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

9.  Fat-water separation with alternating repetition time balanced SSFP.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

10.  Multiple repetition time balanced steady-state free precession imaging.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.