Imaging of the articular cartilage in osteoarthritis of the knee joint: 3D spatial-spectral spoiled gradient-echo vs. fat-suppressed 3D spoiled gradient-echo MR imaging.

Hiroshi Yoshioka1, Marcus Alley, Daniel Steines, Kathryn Stevens, Erika Rubesova, Mark Genovese, Michael F Dillingham, Philipp Lang.   

Abstract

PURPOSE: To compare three-dimensional (3D) spatial-spectral (SS) spoiled gradient-recalled acquisition in the steady state (SPGR) imaging with fat-suppressed 3D SPGR sequences in MR imaging of articular cartilage of the knee joint in patients with osteoarthritis.
MATERIALS AND METHODS: MR images of six patients with osteoarthritis of the knee were prospectively examined with a 1.5T MR scanner. For quantitative analyses, the signal-to-noise ratios, contrast-to-noise ratios, and contrast of cartilage and adjacent structures including meniscus, synovial fluid, muscle, fat tissue, and bone marrow were measured.
RESULTS: In patients with osteoarthritis, 3DSS-SPGR images demonstrated higher spatial resolution and higher mean signal-to-noise (S/N) ratios (cartilage, 24.9; synovial fluid, 12.3; muscle, 20.7; meniscus, 21.6), with shorter acquisition times (7 minutes 20 seconds), when compared to fat-suppressed 3D SPGR images (cartilage, 22.3; synovial fluid, 10.8; muscle, 16.7; meniscus, 13.4).
CONCLUSION: 3DSS-SPGR imaging is a promising method for evaluating cartilage pathology in patients with osteoarthritis of the knee and has the potential to replace fat-suppressed 3D SPGR imaging. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12815641     DOI: 10.1002/jmri.10320

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  Volume rendering based on magnetic resonance imaging: advances in understanding the three-dimensional anatomy of the human knee.

Authors:  Giuseppe Anastasi; Placido Bramanti; Paolo Di Bella; Angelo Favaloro; Fabio Trimarchi; Ludovico Magaudda; Michele Gaeta; Emanuele Scribano; Daniele Bruschetta; Demetrio Milardi
Journal:  J Anat       Date:  2007-07-21       Impact factor: 2.610

2.  Reliability of 3D localisation of ACL attachments on MRI: comparison using multi-planar 2D versus high-resolution 3D base sequences.

Authors:  Vimarsha Gopal Swami; June Cheng-Baron; Catherine Hui; Richard B Thompson; Jacob Lester Jaremko
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-21       Impact factor: 4.342

Review 3.  Routine 3D magnetic resonance imaging of joints.

Authors:  Richard Kijowski; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

Review 4.  Recent advances in MRI of articular cartilage.

Authors:  Garry E Gold; Christina A Chen; Seungbum Koo; Brian A Hargreaves; Neal K Bangerter
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959

5.  Qualitative and quantitative assessment of isotropic ankle magnetic resonance imaging: three-dimensional isotropic intermediate-weighted turbo spin echo versus three-dimensional isotropic fast field echo sequences.

Authors:  Hyun Su Kim; Young Cheol Yoon; Jong Won Kwon; Bong-Keun Choe
Journal:  Korean J Radiol       Date:  2012-06-18       Impact factor: 3.500

6.  Imaging of articular cartilage.

Authors:  Bhawan K Paunipagar; Dd Rasalkar
Journal:  Indian J Radiol Imaging       Date:  2014-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.