Literature DB >> 12813194

Comparison of 99mTc tetrofosmin gated SPECT measurements of left ventricular volumes and ejection fraction with MRI over a wide range of values.

P J Thorley1, S Plein, T N Bloomer, J P Ridgway, U M Sivananthan.   

Abstract

The calculation of ejection fraction using gated single photon emission computed tomography (SPECT) has been widely validated against a range of other techniques. There have been fewer studies validating left ventricular volumes. We compared quantitative gated SPECT (QGS) with magnetic resonance imaging (MRI) measurements of left ventricular ejection fraction and end diastolic volume in 50 patients with a large range of ventricular dimensions. MRI data were obtained using a turbo gradient echo pulse sequence (TGE) in 17 patients and a steady state free precession pulse sequence (SSFP) in 33 patients. There was good correlation between ejection fraction and end diastolic volume measurements from SPECT and MRI (r=0.82, r=0.90, respectively) but the mean SPECT values were significantly lower (ejection fraction, 6.6+/-6.4% points; end diastolic volume, 18.4+/-25.4 ml) than those obtained from MRI. Bland-Altman analysis showed some large differences in individual patients but no trends in the data either in ejection fraction over a range from 15% to 70% or in end diastolic volume, range 75-400 ml. SSFP gave a larger difference for end diastolic volume measurement compared to SPECT than did TGE, although this difference did not reach significance. Both SSFP and TGE gave similar values for the difference between MRI and SPECT for the measurement of ejection fraction. We suggest that the difference in EF may be a result of 8 frames being used for gating in QGS but 12-18 for MR. Differences in volumes may be related to the different spatial resolution and the exclusion or inclusion of trabeculation and papillary muscles between SPECT and MRI. Differences between SSFP and TGE may be caused by differing delineation of the endocardial border, dependent on the particular acquisition sequence. In conclusion, QGS values correlated well with MRI, but a correction factor may be needed if direct comparison is made.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12813194     DOI: 10.1097/00006231-200307000-00005

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  13 in total

1.  Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.

Authors:  Claudia S A Lipke; Harald P Kühl; Bernd Nowak; Hans-Juergen Kaiser; Patrick Reinartz; Karl-Christian Koch; Udalrich Buell; Wolfgang M Schaefer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-14       Impact factor: 9.236

Review 2.  Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

3.  Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach.

Authors:  Guido Germano; Paul B Kavanagh; Piotr J Slomka; Serge D Van Kriekinge; Geoff Pollard; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

4.  Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy.

Authors:  Feng Wang; Jian Zhang; Wei Fang; Shi-Hua Zhao; Min-Jie Lu; Zuo-Xiang He
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-04-18       Impact factor: 9.236

5.  Comparison of 64-slice cardiac computed tomography with myocardial perfusion scintigraphy for assessment of global and regional myocardial function and infarction in patients with low to intermediate likelihood of coronary artery disease.

Authors:  Edward D Nicol; James Stirrup; Eliana Reyes; Michael Roughton; Simon P G Padley; Michael B Rubens; S Richard Underwood
Journal:  J Nucl Cardiol       Date:  2008-06-30       Impact factor: 5.952

6.  Intersecting techniques: the evaluation of left ventricular function with cardiac computed tomography and myocardial perfusion imaging.

Authors:  Gregory S Thomas
Journal:  J Nucl Cardiol       Date:  2008 Jul-Aug       Impact factor: 5.952

Review 7.  Gated SPECT in assessment of regional and global left ventricular function: an update.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Piotr Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

8.  Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Authors:  Wassila Djaballah; Marc A Muller; Anne C Bertrand; Pierre Y Marie; Bernard Chalon; Karim Djaballah; Pierre Olivier; Andreï Codreanu; Gilles Karcher; Alain Bertrand
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

9.  Inter-institution preference-based variability of ejection fraction and volumes using quantitative gated SPECT with 99mTc-tetrofosmin: a multicentre study involving 106 hospitals.

Authors:  Kenichi Nakajima; Tsunehiko Nishimura
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-09-29       Impact factor: 9.236

10.  Gated single photon emission tomography MIBI stress perfusion imaging for assessing cardiac output and index in obese and non-obese patients.

Authors:  J P Coffey; J C Hill
Journal:  Ir J Med Sci       Date:  2007-11-20       Impact factor: 1.568

View more