Literature DB >> 12812450

Aperture modulated arc therapy.

S M Crooks1, Xiaodong Wu, C Takita, M Watzich, Lei Xing.   

Abstract

We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machine output of the accelerator has a constant value. Dose was calculated using the CORVUS 4.0 IMRT system, which uses a pencil beam dose algorithm, and treatments were delivered using a Varian 2100C/D Clinac. Results are presented for a head and neck and a prostate case, showing the equivalence of the IMRT and the translated AMAT delivery. For a prostate AMAT delivery, coronal plane film dose for the IMRT and AMAT deliveries agreed within 7.19 +/- 6.62%. For a meningioma the coronal plane dose distributions were similar to a value of 4.6 +/- 6.62%. Dose to the isocentre was measured as being within 2% of the planned value in both cases.

Entities:  

Mesh:

Year:  2003        PMID: 12812450     DOI: 10.1088/0031-9155/48/10/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Bridging the gap between IMRT and VMAT: dense angularly sampled and sparse intensity modulated radiation therapy.

Authors:  Ruijiang Li; Lei Xing
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

2.  Quality assurance of dynamic parameters in volumetric modulated arc therapy.

Authors:  A Manikandan; B Sarkar; R Holla; T R Vivek; N Sujatha
Journal:  Br J Radiol       Date:  2012-07       Impact factor: 3.039

3.  Dose correction strategy for the optimization of volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Jie Yang; Margie Hunt; Gig Mageras
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

4.  Inverse planning for four-dimensional (4D) volumetric modulated arc therapy.

Authors:  Yunzhi Ma; Daniel Chang; Paul Keall; Yiaoqin Xie; Jae-yoon Park; Tae-suk Suh; Lei Xing
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

5.  The number of beams in IMRT--theoretical investigations and implications for single-arc IMRT.

Authors:  Thomas Bortfeld
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

6.  Optimization approaches to volumetric modulated arc therapy planning.

Authors:  Jan Unkelbach; Thomas Bortfeld; David Craft; Markus Alber; Mark Bangert; Rasmus Bokrantz; Danny Chen; Ruijiang Li; Lei Xing; Chunhua Men; Simeon Nill; Dávid Papp; Edwin Romeijn; Ehsan Salari
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

7.  A comprehensive formulation for volumetric modulated arc therapy planning.

Authors:  Dan Nguyen; Qihui Lyu; Dan Ruan; Daniel O'Connor; Daniel A Low; Ke Sheng
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

8.  A comparison of Monte Carlo dropout and bootstrap aggregation on the performance and uncertainty estimation in radiation therapy dose prediction with deep learning neural networks.

Authors:  Dan Nguyen; Azar Sadeghnejad Barkousaraie; Gyanendra Bohara; Anjali Balagopal; Rafe McBeth; Mu-Han Lin; Steve Jiang
Journal:  Phys Med Biol       Date:  2021-02-24       Impact factor: 3.609

9.  Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT?

Authors:  Gregory T Betzel; Byong Yong Yi; Ying Niu; Cedric X Yu
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

10.  Dual-Gated Volumetric Modulated Arc Therapy.

Authors:  Benjamin Fahimian; Junqing Wu; Huanmei Wu; Sarah Geneser; Lei Xing
Journal:  Radiat Oncol       Date:  2014-09-25       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.