Literature DB >> 12802978

An outbreak of Legionnaire's disease among visitors to a fair in Belgium in 1999.

K De Schrijver1, K Dirven, K Van Bouwel, L Mortelmans, P Van Rossom, T De Beukelaar, C Vael, M Fajo, O Ronveaux, M F Peeters, A Van der Zee, A Bergmans, M Ieven, H Goossens.   

Abstract

This paper describes an outbreak of Legionnaire's disease at Kapellen in Belgium among visitors of the annual fair. The investigation started on 13th November 1999 after a respiratory physician notified the health authorities of the province of Antwerp of presumptive cases of legionellosis. The annual commercial fair at Kapellen, a small town in northern Belgium, was held 10 days previously and attracted 50,000 visitors. Stand employees (professionals or volunteers), technical staff of the hall and visitors at the fair were affected cases. An exploratory case-control study was conducted to trace the source of the epidemic. To complete the inventory study and to evaluate other risk factors, a cohort study of exhibitors and staff was conducted. Ninety-three people met the case definition, 41 of whom were considered as confirmed, 14 as presumptive cases and 38 as possible/clinical cases. Five people died. Further testing at the reference laboratory confirmed all strains to be Legionella pneumophila serogroup 1. The sensitivity for culture was low (29.2%), and sensitivity for seroconversion was high (90.9%). For urinary antigen test, a sensitivity with Biotest EIA of 65.6% was found, and the sensitivity of polymerase chain reaction (PCR) was 85.7%. In all cases, the individual had visited the fair. Those individuals working in the central areas of the tent, near the aerosol-producing devices, were at higher risk of disease. Legionella was detected by PCR on swabs of the surfaces of the whirlpool. Although not fully proven, an aerosol-producing device was the most probable source of the outbreak.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12802978     DOI: 10.1016/S0033-3506(02)00011-2

Source DB:  PubMed          Journal:  Public Health        ISSN: 0033-3506            Impact factor:   2.427


  5 in total

1.  Aerosolization of respirable droplets from a domestic spa pool and the use of MS-2 coliphage and Pseudomonas aeruginosa as markers for Legionella pneumophila.

Authors:  Ginny Moore; Matthew Hewitt; David Stevenson; Jimmy T Walker; Allan M Bennett
Journal:  Appl Environ Microbiol       Date:  2014-11-07       Impact factor: 4.792

2.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

3.  Barrow-in-Furness: a large community legionellosis outbreak in the UK.

Authors:  E Bennett; M Ashton; N Calvert; J Chaloner; J Cheesbrough; J Egan; I Farrell; I Hall; T G Harrison; F C Naik; S Partridge; Q Syed; R N Gent
Journal:  Epidemiol Infect       Date:  2013-10-11       Impact factor: 4.434

4.  A cluster of Legionnaires' disease in Belgium linked to a cooling tower, August-September 2016: practical approach and challenges.

Authors:  N Hammami; V Laisnez; I Wybo; D Uvijn; C Broucke; A Van Damme; L Van Zandweghe; W Bultynck; W Temmerman; L Van De Ginste; T Moens; E Robesyn
Journal:  Epidemiol Infect       Date:  2019-12-20       Impact factor: 2.451

5.  Restaurant outbreak of Legionnaires' disease associated with a decorative fountain: an environmental and case-control study.

Authors:  Rosalyn E O'Loughlin; Lon Kightlinger; Matthew C Werpy; Ellen Brown; Valerie Stevens; Clark Hepper; Tim Keane; Robert F Benson; Barry S Fields; Matthew R Moore
Journal:  BMC Infect Dis       Date:  2007-08-09       Impact factor: 3.090

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.