Aerosolization of respirable droplets from a domestic spa pool and the use of MS-2 coliphage and Pseudomonas aeruginosa as markers for Legionella pneumophila.

Ginny Moore1, Matthew Hewitt2, David Stevenson2, Jimmy T Walker2, Allan M Bennett2.   

Abstract

Legionnaires' disease can result when droplets or aerosols containing legionella bacteria are inhaled and deposited in the lungs. A number of outbreaks have been associated with the use of a spa pool where aeration, a high water temperature, and a large and variable organic load make disinfectant levels difficult to maintain. Spa pool ownership is increasing, and the aim of this study, using two surrogate organisms (MS-2 coliphage and Pseudomonas aeruginosa [a natural contaminant]), was to assess the potential risk to domestic users when disinfection fails. A representative "entry level" domestic spa pool was installed in an outdoor courtyard. The manufacturer's instructions for spa pool maintenance were not followed. A cyclone sampler was used to sample the aerosols released from the spa pool with and without activation of the air injection system. Samples were taken at increasing heights and distances from the pool. An aerodynamic particle sizer was used to measure the water droplet size distribution at each sample point. When the air injection system was inactivated, neither surrogate organism was recovered from the air. On activation of the air injection system, the mean mass of droplets within the respirable range (10 cm above the water line) was 36.8 μg cm(-3). This corresponded to a mean air concentration of P. aeruginosa of 350 CFU m(-3). From extrapolation from animal data, the estimated risk of infection from aerosols contaminated with similar concentrations of Legionella pneumophila was 0.76 (males) and 0.65 (females). At 1 m above and/or beyond the pool, the mean aerosol mass decreased to 0.04 μg cm(-3) and corresponded to a 100-fold reduction in mean microbial air concentration. The estimated risk of infection at this distance was negligible.
Copyright © 2015, American Society for Microbiology. All Rights Reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25381233      PMCID: PMC4277565          DOI: 10.1128/AEM.02912-14

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  31 in total

1.  Quantitative microbial risk assessment model for Legionnaires' disease: assessment of human exposures for selected spa outbreaks.

Authors:  Thomas W Armstrong; Charles N Haas
Journal:  J Occup Environ Hyg       Date:  2007-08       Impact factor: 2.155

2.  Outbreak of Legionnaires' disease on a cruise ship linked to spa-bath filter stones contaminated with Legionella pneumophila serogroup 5.

Authors:  F Kura; J Amemura-Maekawa; K Yagita; T Endo; M Ikeno; H Tsuji; M Taguchi; K Kobayashi; E Ishii; H Watanabe
Journal:  Epidemiol Infect       Date:  2006-04       Impact factor: 2.451

3.  Microbial aerosol generation during laboratory accidents and subsequent risk assessment.

Authors:  A Bennett; S Parks
Journal:  J Appl Microbiol       Date:  2006-04       Impact factor: 3.772

4.  An outbreak of Legionnaires' disease associated with a display spa pool in retail premises, Stoke-on-Trent, United Kingdom, July 2012.

Authors:  N Coetzee; H Duggal; J Hawker; S Ibbotson; T G Harrison; N Phin; V Laza-Stanca; R Johnston; Z Iqbal; Y Rehman; E Knapper; S Robinson; N Aigbogun
Journal:  Euro Surveill       Date:  2012-09-13

5.  Prevalence and significance of Legionella pneumophila contamination of residential hot-tap water systems.

Authors:  P M Arnow; D Weil; M F Para
Journal:  J Infect Dis       Date:  1985-07       Impact factor: 5.226

6.  Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures.

Authors:  R M Wadowsky; R B Yee; L Mezmar; E J Wing; J N Dowling
Journal:  Appl Environ Microbiol       Date:  1982-05       Impact factor: 4.792

7.  Pontiac fever due to Legionella micdadei from a whirlpool spa: possible role of bacterial endotoxin.

Authors:  B S Fields; T Haupt; J P Davis; M J Arduino; P H Miller; J C Butler
Journal:  J Infect Dis       Date:  2001-10-02       Impact factor: 5.226

8.  Growth of Pseudomonas aeruginosa in tap water in relation to utilization of substrates at concentrations of a few micrograms per liter.

Authors:  D van der Kooij; J P Oranje; W A Hijnen
Journal:  Appl Environ Microbiol       Date:  1982-11       Impact factor: 4.792

9.  Aerosol infection of animals with strains of Legionella pneumophila of different virulence: comparison with intraperitoneal and intranasal routes of infection.

Authors:  R B Fitzgeorge; A Baskerville; M Broster; P Hambleton; P J Dennis
Journal:  J Hyg (Lond)       Date:  1983-02

10.  Prevalence and antimicrobial-resistance of Pseudomonas aeruginosa in swimming pools and hot tubs.

Authors:  Jonathan K Lutz; Jiyoung Lee
Journal:  Int J Environ Res Public Health       Date:  2011-02-18       Impact factor: 3.390

View more
  2 in total

1.  Evaluation of Exposure to Brevundimonas diminuta and Pseudomonas aeruginosa during Showering.

Authors:  Sandip Chattopadhyay; Sarah D Perkins; Matthew Shaw; Tonya L Nichols
Journal:  J Aerosol Sci       Date:  2017-12       Impact factor: 3.433

2.  Characterization of aerosols containing Legionella generated upon nebulization.

Authors:  Séverine Allegra; Lara Leclerc; Pierre André Massard; Françoise Girardot; Serge Riffard; Jérémie Pourchez
Journal:  Sci Rep       Date:  2016-09-27       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.