[Rotational stability in intraocular lenses with C-loop haptics versus Z haptics in cataract surgery. A prospective randomised comparison].

I Warlo1, F Krummenauer, H B Dick.   

Abstract

The aim of the study was to compare the rotational stability of intraocular lenses (IOLs) with C-loop haptics and those with Z haptics. A total of 50 patients with cataracts were prospectively randomised in equal numbers using a design equivalent to IOL MS 612 S (C-loop haptic) and MS 6120 (Z haptic, both HumanOptics, Erlangen). Complete ophthalmological examinations were performed including assessment of the IOL rotation after 1 day, 1 month and 3 months postoperatively. The significances between the groups were evaluated using the Wilcoxon test. The Fisher exact test was used for the primary finding of the study (rotation of at least 10 degrees ). The IOL group with the C-loop haptics showed a median lens rotation of 0 degrees on the first day and 2 degrees clockwise after 1 month and 3 months. In the Z haptic group, there was no median rotation in the IOL group. Moreover, the range of IOL rotation of the C-loop haptics was broader (3 months postoperatively: maximum in the C-loop haptics: 21 degrees with 15.5 degrees in the Z haptics). There was no significant difference at any time. At 3 months postoperatively, 32% of the C-loop haptic IOL and 16% of the Z haptic IOL rotated at least 10 degrees (P=0.32). In 59% of the IOL with C-loop haptics, the direction of the rotation was clockwise. This was 40% for the IOL with Z haptics (P=0.33). At 3 months postoperatively, both IOLs demonstrated good rotational stability with a low mean deviation from the target axis. IOLs with Z haptics showed a tendency to greater rotational stability than C-loop haptics but without any significant difference. There was no significant difference in visual rehabilitation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15785909     DOI: 10.1007/s00347-005-1213-7

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  14 in total

1.  Correcting high astigmatism with piggyback toric intraocular lens implantation.

Authors:  James P Gills; Michelle A Van der Karr
Journal:  J Cataract Refract Surg       Date:  2002-03       Impact factor: 3.351

Review 2.  [Comparison of intraocular lenses--a review].

Authors:  H B Dick; A J Augustin
Journal:  Klin Monbl Augenheilkd       Date:  2001-07       Impact factor: 0.700

3.  Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases.

Authors:  David F Chang
Journal:  J Cataract Refract Surg       Date:  2003-05       Impact factor: 3.351

4.  Decentration of flexible loop posterior chamber intraocular lenses in a series of 222 postmortem eyes.

Authors:  S O Hansen; M R Tetz; K D Solomon; M D Borup; R N Brems; D J O'Morchoe; O Bouhaddou; D J Apple
Journal:  Ophthalmology       Date:  1988-03       Impact factor: 12.079

5.  Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants.

Authors:  C K Patel; S Ormonde; P H Rosen; A J Bron
Journal:  Ophthalmology       Date:  1999-11       Impact factor: 12.079

6.  Decentration associated with asymmetric capsular shrinkage and intraocular lens size.

Authors:  S Ohmi
Journal:  J Cataract Refract Surg       Date:  1993-09       Impact factor: 3.351

7.  Biometry of 7,500 cataractous eyes.

Authors:  K J Hoffer
Journal:  Am J Ophthalmol       Date:  1980-09       Impact factor: 5.258

8.  Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ring.

Authors:  K Strenn; R Menapace; C Vass
Journal:  J Cataract Refract Surg       Date:  1997-12       Impact factor: 3.351

9.  Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism.

Authors:  A Frohn; H B Dick; H J Thiel
Journal:  J Cataract Refract Surg       Date:  1999-12       Impact factor: 3.351

10.  Combined toric intraocular lens implantation and relaxing incisions to reduce high preexisting astigmatism.

Authors:  James p Gills; Michelle Van der Karr; Myra Cherchio
Journal:  J Cataract Refract Surg       Date:  2002-09       Impact factor: 3.351

View more
  3 in total

1.  Refractive predictability in eyes with intraocular gas tamponade - results of a prospective controlled clinical trial.

Authors:  Lars Wagenfeld; Kristin Hermsdorf; Birthe Stemplewitz; Vasyl Druchkiv; Andreas Frings
Journal:  Clin Ophthalmol       Date:  2017-05-23

2.  Rotational stability of the AcrySof SA60TT toric intraocular lenses: a cohort study.

Authors:  Bruno Zuberbuhler; Theo Signer; Richard Gale; Eduard Haefliger
Journal:  BMC Ophthalmol       Date:  2008-05-06       Impact factor: 2.209

3.  Efficacy of Toric intraocular lens implantation in eyes with high myopia: A prospective, case-controlled observational study.

Authors:  Tao Guo; Peng Gao; Li Fang; Li Guo; Yuchen Fan; Changgen Liu
Journal:  Exp Ther Med       Date:  2018-04-25       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.